ETE MV150P3S3 Multi-Voltage Control Transformer 150VA 0/120V + 0/120V to 0/12V + 0/12V

ETE MV150P3S3 Multi-Voltage Control Transformer 150VA 0/120V + 0/120V to 0/12V + 0/12V

ETE MV150P3S3 is a 150 VA single-phase multi-voltage control transformer with dual 120 V primary windings configurable for 120 V parallel or 240 V series operation, dual 12 V secondary windings configurable for 12 V parallel or 24 V series output, Class E insulation and 10% voltage regulation.

SKU: MV150P3S3MPN: MV150P3S3
Price
List Price £43.90 ex VAT
Your Price (ex VAT)
£43.90
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £43.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£43.90

Why Choose the ETE MV150P3S3 150 VA Multi-Voltage Control Transformer?

The ETE MV150P3S3 is a versatile 150 VA single-phase multi-voltage control transformer featuring dual 120 V primary windings and dual 12 V secondary windings. Part of the ETE MV Multi-Voltage Series, it provides flexible electrical connections for industrial control panels, machinery, automation systems and OEM equipment requiring a nominal 12 V AC or 24 V AC output.

Its 0/120 V + 0/120 V primary terminals allow the two primary windings to be connected in parallel for a 120 V AC supply or in series for a 240 V AC supply. The 0/12 V + 0/12 V secondary terminals offer corresponding flexibility, with parallel connection providing 12 V AC and series connection providing 24 V AC.

With Class E insulation, 10% voltage regulation, dimensions of 96 × 76 × 103 mm and a weight of 2.3 kg, the MV150P3S3 provides a compact control power solution. The specified enclosure references are EPH 2 or EPN 1.

Key Advantages

  • Dual primary voltage configuration: Connect the two 120 V primary windings in parallel for 120 V AC or in series for 240 V AC.
  • Selectable secondary voltage: Configure the two 12 V secondary windings for 12 V AC parallel or 24 V AC series operation.
  • 150 VA rated capacity: Suitable for appropriately sized industrial control and signalling circuits.
  • Flexible electrical design: Accommodates two primary supply voltages and two secondary output configurations.
  • Class E insulation: Provides a defined insulation classification for industrial transformer applications.
  • 10% voltage regulation: Supports informed selection of connected equipment where loading conditions vary.
  • Continuous-rated operation: Designed for industrial control circuit applications.
  • IP20 touch-proof terminals: Help reduce accidental contact with electrical terminal connections.
  • Class H varnish impregnation: Supports the durability of the transformer windings.
  • Protective core earth connection: Facilitates appropriate protective earthing.
  • Compact construction: Measures 96 × 76 × 103 mm for integration into control cabinets.
  • DIN rail mounting option: Offers additional flexibility for suitable panel installations.
  • Enclosure options: Specified references EPH 2 or EPN 1.

Key Features

  • ETE MV Multi-Voltage Series control transformer.
  • 150 VA rated apparent power.
  • Single-phase transformer configuration.
  • 0/120 V + 0/120 V primary terminal arrangement.
  • Two individual 120 V AC primary windings.
  • 120 V AC primary operation with correctly phased parallel windings.
  • 240 V AC primary operation with correctly phased series windings.
  • 0/12 V + 0/12 V secondary terminal arrangement.
  • Two individual 12 V AC secondary windings.
  • 12 V AC secondary output with parallel winding connection.
  • 24 V AC secondary output with series-aiding winding connection.
  • 50/60 Hz operating frequency.
  • Class E insulation system.
  • 10% voltage regulation.
  • Continuous-rated control circuit transformer.
  • IP20 touch-proof terminals.
  • Class H varnish-impregnated windings.
  • Protective core earth connection.
  • Designed to EN 61558-1.
  • Specified ambient temperature range of −10 to +35 °C.
  • DIN rail mounting option.
  • 96 × 76 × 103 mm overall dimensions.
  • 2.3 kg product weight.
  • EPH 2 or EPN 1 enclosure references.

Dual 120 V Primary Windings for 120 V or 240 V AC Operation

The ETE MV150P3S3 incorporates two separate 0/120 V primary windings, providing a flexible alternative to a transformer with a single fixed primary voltage. This design allows the transformer to operate from either a nominal 120 V AC or 240 V AC supply, depending on how the primary windings are connected.

120 V AC Parallel Primary Connection

For a nominal 120 V AC supply, the two primary windings are connected in parallel according to the manufacturer's wiring diagram. Correct winding polarity is essential to prevent opposing connections and potentially damaging circulating currents.

240 V AC Series Primary Connection

For a nominal 240 V AC supply, the two 120 V primary windings are connected in series, allowing the supply voltage to be shared across the windings. The correct series connection must be established using the manufacturer's terminal identification and connection instructions.

This dual-primary arrangement makes the MV150P3S3 suitable for electrical panel builders and OEM machinery manufacturers producing equipment for installations with different supply voltages. The primary winding configuration must be selected before energisation, and the manufacturer's wiring diagram must be followed.

Dual 12 V Secondary Windings for 12 V or 24 V AC Output

The transformer features two separate 0/12 V secondary windings, enabling a nominal 12 V AC or 24 V AC output depending on the selected winding arrangement. This provides flexibility for industrial control circuits requiring different low-voltage AC supplies.

12 V AC Parallel Secondary Connection

When the two 12 V secondary windings are connected correctly in parallel, the transformer provides a nominal 12 V AC output. Based on its total 150 VA rating, the calculated full-load output current is approximately 12.5 A.

Parallel connection requires the windings to have the correct polarity and matching voltages. Incorrect connections may cause excessive circulating current, overheating or transformer damage. The manufacturer's connection diagram should always be followed.

24 V AC Series Secondary Connection

When the two secondary windings are connected in the correct series-aiding arrangement, their voltages combine to provide a nominal 24 V AC output. At 150 VA, the calculated full-load secondary current is approximately 6.25 A.

This configuration is suitable for appropriately rated 24 V AC control equipment, including relays, contactors, actuators and signalling devices. The total load, switching inrush and voltage regulation requirements should be considered during transformer selection.

Engineering note: The calculated output currents assume the full 150 VA rating is available in the selected winding configuration. The manufacturer's connection instructions, permissible winding loading and terminal ratings should be checked before installation.

Compact Industrial Construction and Installation Flexibility

With dimensions of 96 mm in length, 76 mm in width and 103 mm in height, the MV150P3S3 is well suited to installation within industrial control panels and electrical machinery cabinets. Its 2.3 kg weight allows it to be accommodated within appropriately designed mounting arrangements.

The transformer features Class E insulation, Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection. It is designed to EN 61558-1 for continuous-rated control circuit applications, with a specified ambient temperature range of −10 to +35 °C.

A DIN rail mounting option is available for this transformer size, providing flexibility for compatible panel installations. The specified enclosure references are EPH 2 or EPN 1. Suitable mechanical support, ventilation, conductor sizing, protective earthing and electrical protection should be incorporated into the complete installation.

Typical Applications

  • Industrial control panels requiring 12 V AC or 24 V AC supplies.
  • Machinery control systems operating from 120 V AC or 240 V AC primary supplies.
  • Industrial contactor and relay control circuits.
  • 24 V AC actuators and compatible control devices.
  • 12 V AC switching and signalling equipment.
  • Motor starter and motor control assemblies.
  • Factory automation and production machinery.
  • OEM machinery and electrical equipment manufacturing.
  • Electrical control panel building and system integration.
  • Industrial machinery refurbishment and maintenance.
  • Applications requiring configurable dual primary and dual secondary windings.
  • Electrical installations requiring a compact 150 VA single-phase control transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer Eastern Transformers & Equipment (ETE)
Rated Power (VA) 150 VA
Primary Voltage 0/120V + 0/120V
Secondary Voltage 0/12V + 0/12V
Phase Single Phase
Manufacturer part number MV150P3S3
Product series MV Multi-Voltage Series
Product type Multi-voltage control circuit transformer
Number of phases Single-phase
Rated apparent power 150 VA
Primary terminals 0/120 V + 0/120 V
Number of primary windings Two
Individual primary winding voltage 120 V AC
Parallel primary connection 120 V AC
Series primary connection 240 V AC
Secondary terminals 0/12 V + 0/12 V
Number of secondary windings Two
Individual secondary winding voltage 12 V AC
Parallel secondary output 12 V AC
Series secondary output 24 V AC
Calculated secondary current at 12 V Approximately 12.5 A, based on 150 VA with correctly connected parallel windings
Calculated secondary current at 24 V Approximately 6.25 A, based on 150 VA with correctly connected series windings
Operating frequency 50/60 Hz
Insulation class E
Voltage regulation 10%
Terminal protection IP20 touch-proof terminals
Winding impregnation Class H varnish
Core earth connection Provided
Ambient operating temperature −10 to +35 °C
Design standard EN 61558-1
Duty rating Continuous
Mounting Panel mounting; DIN rail mounting option
Length 96 mm
Width 76 mm
Height 103 mm
Dimensions (L × W × H) 96 × 76 × 103 mm
Weight 2.3 kg
Enclosure references EPH 2 or EPN 1
Manufacturer catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV150P3S3 control transformer used for?

The ETE MV150P3S3 is a 150 VA single-phase multi-voltage control transformer used to supply compatible industrial control circuits requiring 12 V AC or 24 V AC. Its dual primary windings also support connection to either a 120 V AC or 240 V AC supply.

Can the ETE MV150P3S3 operate from both 120 V and 240 V supplies?

Yes. The transformer has two 0/120 V primary windings. Correctly connecting these windings in parallel provides 120 V AC primary operation, while connecting them in series provides 240 V AC primary operation. The manufacturer's winding polarity and wiring instructions must be followed.

How does the MV150P3S3 provide 12 V or 24 V AC output?

The transformer has two 0/12 V secondary windings. Connecting them correctly in parallel provides a nominal 12 V AC output, while a correctly phased series connection provides a nominal 24 V AC output.

What is the calculated secondary current at 12 V AC?

At the full 150 VA rating, the calculated secondary current is approximately 12.5 A at 12 V AC when the two secondary windings are correctly connected in parallel, subject to the manufacturer's permitted winding and terminal ratings.

What is the calculated secondary current at 24 V AC?

With the secondary windings correctly connected in series, the 150 VA rating corresponds to a calculated nominal secondary current of approximately 6.25 A at 24 V AC.

Why is correct winding polarity important?

Correct winding polarity is essential when connecting the primary or secondary windings in series or parallel. Incorrect connections can produce unintended voltages or excessive circulating currents. The manufacturer's terminal markings and wiring diagram must be followed before energising the transformer.

What are the dimensions and weight of the ETE MV150P3S3?

The transformer measures 96 × 76 × 103 mm (length × width × height) and weighs 2.3 kg.

What insulation class and voltage regulation does the MV150P3S3 have?

The MV150P3S3 features Class E insulation and 10% voltage regulation. It also incorporates Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection.

Which enclosures are specified for the ETE MV150P3S3?

The manufacturer's specified enclosure references are EPH 2 or EPN 1. The final enclosure and mounting arrangement should provide suitable ventilation, mechanical support and electrical protection.

Trusted by Industrial Panel Builders and Automation Engineers

The ETE MV150P3S3 offers a flexible industrial control power solution with a 150 VA rating, dual 120 V primary windings and dual 12 V secondary windings. Its configurable 120 V or 240 V input and 12 V or 24 V output arrangements, combined with Class E insulation, 10% voltage regulation and EPH 2 or EPN 1 enclosure options, make it a practical choice for industrial panel builders, OEM machinery manufacturers and automation engineers.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...