ETE MV400P2S1 Multi-Voltage Control Transformer 400VA 20/0/380/420V to 0/55/110V

ETE MV400P2S1 Multi-Voltage Control Transformer 400VA 20/0/380/420V to 0/55/110V

ETE MV400P2S1 is a 400 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary taps, Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure references.

SKU: MV400P2S1MPN: MV400P2S1
Price
List Price £85.30 ex VAT
Your Price (ex VAT)
£85.30
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £85.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£85.30

Why Choose the ETE MV400P2S1 400 VA Multi-Voltage Control Transformer?

The ETE MV400P2S1 is a 400 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring a nominal 55 V AC or 110 V AC control supply. Part of the ETE MV Multi-Voltage Series, it features 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, providing flexible voltage connections for industrial control applications.

The transformer is suited to installations where a higher-voltage AC supply must be converted to a lower-voltage control circuit supply. Its multi-tapped primary arrangement includes 380 V and 420 V terminal markings, while its secondary winding provides selectable 55 V and 110 V output taps. The precise primary connections must be selected using the manufacturer's approved wiring instructions.

With a 400 VA rated capacity, Class E insulation and 8% voltage regulation, the MV400P2S1 provides a practical solution for appropriately rated control equipment. It measures 120 × 108 × 120 mm, weighs 5.5 kg and has specified enclosure references of EPH 3 or EPN 2.

Important connection note: The primary winding includes a 20 V adjustment tap. The exact terminal connections and adjustment method must be confirmed with ETE before installation or energisation.

Key Advantages

  • 400 VA rated capacity: Provides apparent power for appropriately sized industrial control, switching and signalling circuits.
  • Multi-voltage primary: Features 20/0/380/420 V terminals for manufacturer-specified industrial supply arrangements.
  • Selectable secondary voltage: Provides nominal 55 V AC or 110 V AC output connections.
  • Tapped secondary winding: Allows selection between two control voltage levels without changing transformer models.
  • 20 V primary adjustment tap: Offers an additional winding connection feature, subject to ETE confirmation.
  • 8% voltage regulation: Provides a specified regulation characteristic for control circuit design.
  • Class E insulation: Offers a defined insulation classification.
  • Industrial control applications: Suitable for compatible relays, contactors and machinery control equipment.
  • Compact construction: Measures 120 × 108 × 120 mm for integration into electrical cabinets.
  • Defined installation weight: Weighs 5.5 kg for mechanical mounting considerations.
  • Enclosure flexibility: Specified enclosure references EPH 3 or EPN 2.

Key Features

  • ETE MV Multi-Voltage Series industrial control transformer.
  • 400 VA rated apparent power.
  • Single-phase transformer configuration.
  • 20/0/380/420 V primary terminal arrangement.
  • 380 V and 420 V primary terminal markings.
  • 20 V primary adjustment tap requiring manufacturer connection confirmation.
  • 0/55/110 V secondary terminal arrangement.
  • Nominal 55 V AC or 110 V AC secondary output connections.
  • Class E insulation.
  • 8% specified voltage regulation.
  • 120 mm length.
  • 108 mm width.
  • 120 mm height.
  • 5.5 kg weight.
  • EPH 3 or EPN 2 enclosure references.
  • Listed in the ETE Stock Control Transformer Range, March 2026.

Multi-Voltage Primary Connections and 20 V Adjustment Tap

The ETE MV400P2S1 features a 20/0/380/420 V primary terminal arrangement, allowing connection to the industrial AC supply configurations specified by ETE. The primary winding includes terminals marked for nominal 380 V and 420 V arrangements, together with an additional 20 V terminal.

This flexibility is useful for panel builders and machinery manufacturers designing electrical control equipment for different supply voltage requirements. The correct connection must be selected according to the available supply and the manufacturer's approved terminal diagram.

The 20 V primary adjustment tap provides an additional connection feature, but the exact adjustment method must not be inferred solely from the terminal markings.

Installation requirement: Confirm the correct primary connections, including the 20 V adjustment tap, with ETE before energising the transformer. Incorrect connections can result in unintended secondary voltages or transformer damage.

Selectable 55 V and 110 V AC Secondary Output

The MV400P2S1 incorporates 0/55/110 V secondary terminals, providing two nominal secondary voltage options for compatible industrial control circuits.

110 V AC Secondary Connection

When the full secondary winding is connected for a nominal 110 V AC output, the transformer's 400 VA rating corresponds to a calculated output current of approximately 3.64 A.

This arrangement is suitable for appropriately rated 110 V AC control equipment, including contactor coils, relays, switching circuits and machinery control devices.

55 V AC Secondary Tap

The intermediate secondary terminal provides a nominal 55 V AC output connection. This is useful where compatible industrial control equipment requires a lower AC control voltage.

Dividing the total transformer rating by 55 V produces a theoretical current of approximately 7.27 A. However, this calculation does not establish the permissible current or apparent power available from the individual 55 V winding section.

Engineering consideration: Confirm the permissible 55 V tap loading with ETE before designing a circuit around the theoretical current. The transformer rating must not be assumed to apply independently to every tap.

8% Voltage Regulation for Industrial Control Circuits

The MV400P2S1 has a specified 8% voltage regulation characteristic. Voltage regulation describes the variation in secondary voltage as transformer loading changes under the relevant operating conditions.

This characteristic should be considered when selecting voltage-sensitive industrial control devices, particularly contactors and relays that may experience short-duration switching inrush currents.

For correct transformer selection, engineers should consider the total connected apparent power, expected operating load, starting or energisation demands and the permissible voltage range of the connected equipment.

Industrial Construction and Installation Considerations

The ETE MV400P2S1 measures 120 mm in length, 108 mm in width and 120 mm in height, with a specified weight of 5.5 kg. These dimensions allow electrical panel builders to plan mounting space and mechanical support within appropriately designed control cabinets.

The transformer has Class E insulation, and the manufacturer's specified enclosure references are EPH 3 or EPN 2. The enclosure and mounting arrangement should be selected to provide suitable ventilation, mechanical protection and accessibility for the intended installation.

Primary and secondary circuit protection, conductor sizing, protective earthing and terminal connections should be designed in accordance with the applicable electrical installation requirements and ETE's technical instructions.

The manufacturer's approved connection diagram should be used to verify the primary adjustment tap and secondary voltage selection before commissioning.

Typical Applications

  • Industrial control panels requiring nominal 110 V AC control power.
  • Control circuits requiring a nominal 55 V AC secondary tap.
  • Industrial contactor and relay control systems.
  • Motor starter and motor control equipment.
  • Factory automation and production machinery.
  • OEM machinery and electrical equipment manufacturing.
  • Industrial switching and signalling circuits.
  • Electrical control voltage adaptation from higher-voltage AC supplies.
  • Control cabinet assembly and electrical panel building.
  • Industrial maintenance and machinery refurbishment.
  • Replacement transformer applications where the electrical ratings and dimensions are suitable.
  • Applications requiring a 400 VA single-phase multi-voltage control transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Brand ETE
Rated Power (VA) 400 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 0/55/110V
Phase Single Phase
Manufacturer part number MV400P2S1
Product series MV Multi-Voltage Series
Product category Control Transformers
Transformer type Multi-voltage control transformer
Phase configuration Single-phase
Rated apparent power 400 VA
Primary terminals 20/0/380/420 V
Primary adjustment tap 20 V — confirm connections with ETE
Secondary terminals 0/55/110 V
Secondary output connections 55 V AC or 110 V AC taps
Calculated secondary current at 110 V Approximately 3.64 A at 400 VA
55 V tap current Permissible loading requires manufacturer confirmation
Insulation class E
Voltage regulation 8%
Length 120 mm
Width 108 mm
Height 120 mm
Dimensions (L × W × H) 120 × 108 × 120 mm
Weight 5.5 kg
Enclosure references EPH 3 or EPN 2
Manufacturer catalogue ETE Stock Control Transformer Range
Catalogue date March 2026

Frequently Asked Questions

What is the ETE MV400P2S1 control transformer used for?

The ETE MV400P2S1 is a 400 VA single-phase multi-voltage control transformer designed to supply compatible industrial control circuits requiring nominal 55 V AC or 110 V AC. Typical applications include machinery control panels, contactors, relays and automation equipment.

What primary voltage terminals does the ETE MV400P2S1 have?

The transformer features 20/0/380/420 V primary terminals, including a 20 V adjustment tap. The correct connections must be confirmed with ETE and selected according to the manufacturer's approved wiring diagram.

Can the MV400P2S1 provide both 55 V and 110 V AC?

Yes. The transformer has 0/55/110 V secondary terminals, providing nominal 55 V AC and 110 V AC output connections. The permissible loading of the 55 V tap must be confirmed with ETE.

What is the calculated secondary current at 110 V AC?

At the full 400 VA rating, the calculated nominal secondary current is approximately 3.64 A at 110 V AC. The connected load and any switching inrush requirements should also be considered.

Can the full 400 VA rating be drawn from the 55 V tap?

Not without manufacturer confirmation. The 400 VA rating applies to the transformer but does not independently establish the permissible current or apparent power available from the individual 55 V winding section. Confirm the tap loading limits with ETE.

What is the purpose of the 20 V primary adjustment tap?

The 20 V primary adjustment tap forms part of the transformer's multi-voltage winding arrangement. Its exact function and terminal connections must be confirmed with ETE before installation or energisation.

What are the dimensions, insulation class and enclosure options of the MV400P2S1?

The transformer measures 120 × 108 × 120 mm, weighs 5.5 kg, has Class E insulation and 8% voltage regulation, and has specified enclosure references of EPH 3 or EPN 2.

Trusted by Industrial Panel Builders and Automation Engineers

The ETE MV400P2S1 combines a 400 VA rating, 20/0/380/420 V primary terminals and selectable 55 V or 110 V secondary connections in a compact industrial control transformer. With Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure options, it provides a flexible solution for electrical panel builders, OEM machinery manufacturers and industrial maintenance engineers. Confirm the 20 V primary adjustment tap connections and permissible secondary tap loading with ETE before commissioning.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...