ETE MV400P2S3 is a 400 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, dual 0/12 V secondary windings configurable for 12 V parallel or 24 V series output, a 20 V primary adjustment tap requiring ETE connection confirmation, Class E insulation and 8% voltage regulation.

SKU: MV400P2S3MPN: MV400P2S3
Price
List Price £85.30 ex VAT
Your Price (ex VAT)
£85.30
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £85.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£85.30

Why Choose the ETE MV400P2S3 400 VA Multi-Voltage Control Transformer?

The ETE MV400P2S3 is a 400 VA single-phase multi-voltage control transformer designed for industrial electrical installations requiring flexible primary voltage connections and selectable low-voltage AC outputs. Part of the ETE MV multi-voltage transformer series, it features 20/0/380/420 V primary terminals and two separate secondary windings, each marked 0/12 V.

The MV400P2S3 supports a nominal 12 V AC output with the secondary windings connected in parallel or a nominal 24 V AC output with the secondary windings connected in series. This flexibility makes it suitable for industrial control panels, OEM machinery and automation equipment requiring compatible 12 V or 24 V AC control supplies.

The transformer incorporates a 20 V primary adjustment tap alongside its 0/380/420 V primary terminal markings. This provides an additional connection facility within the primary winding arrangement. The correct use of the 20 V adjustment tap and the required primary terminal connections must be confirmed with ETE before installation. The terminal markings should not be used to infer an unverified adjustment connection.

With Class E insulation, 8% voltage regulation, dimensions of 120 × 108 × 120 mm and a weight of 5.5 kg, the ETE MV400P2S3 offers a practical solution for industrial control power distribution. Its associated enclosure references are EPH 3 or EPN 2, supporting enclosure selection and electrical panel planning.

Key Advantages

  • 400 VA rated capacity: Provides dedicated AC power for compatible industrial control circuits and automation equipment.
  • Multi-voltage primary arrangement: Incorporates 20/0/380/420 V terminals for the manufacturer's specified primary connection configurations.
  • 12 V AC parallel output: Supports compatible low-voltage control and signalling equipment.
  • 24 V AC series output: Provides an alternative control voltage for compatible industrial devices.
  • Dual secondary windings: Two 0/12 V winding groups allow flexible output configuration.
  • 20 V primary adjustment tap: Provides an additional primary connection facility, subject to confirmation of the correct wiring arrangement with ETE.
  • Single-phase construction: Suitable for dedicated AC control voltage transformation.
  • Class E insulation: Provides a defined thermal insulation classification.
  • 8% voltage regulation: Provides a specified indication of secondary voltage variation under changing load conditions.
  • Compact transformer dimensions: The 120 × 108 × 120 mm format assists with electrical panel space planning.
  • 5.5 kg weight: Enables suitable mechanical support and mounting arrangements to be specified.
  • EPH 3 or EPN 2 enclosure references: Help identify associated enclosure options for installation planning.
  • Flexible output selection: Supports two commonly used low-voltage AC control supply arrangements.
  • Industrial control transformer design: Suitable for integration into appropriately protected machinery and automation circuits.

Key Features

  • ETE MV multi-voltage control transformer series.
  • 400 VA rated apparent power.
  • 0.4 kVA transformer capacity.
  • Single-phase transformer configuration.
  • Primary terminal arrangement: 20/0/380/420 V.
  • Primary voltage terminal markings: 380 V and 420 V.
  • Primary adjustment tap: 20 V.
  • Primary connection requirement: Confirm correct adjustment tap connections with ETE.
  • Secondary winding 1: 0/12 V.
  • Secondary winding 2: 0/12 V.
  • Parallel secondary configuration: 12 V AC.
  • Series secondary configuration: 24 V AC.
  • Winding connection flexibility: Supports series or parallel connection of the two secondary windings.
  • Insulation class: E.
  • Specified voltage regulation: 8%.
  • Length: 120 mm.
  • Width: 108 mm.
  • Height: 120 mm.
  • Weight: 5.5 kg.
  • Associated enclosure references: EPH 3 or EPN 2.

Flexible 12 V and 24 V AC Control Power for Industrial Automation

The ETE MV400P2S3 provides a practical solution for industrial installations requiring a dedicated low-voltage AC supply from a compatible higher-voltage primary source. Its 20/0/380/420 V primary terminal arrangement incorporates nominal 380 V and 420 V connection positions alongside a 20 V adjustment tap. The correct primary supply and adjustment connections must be confirmed with ETE before energising the transformer.

A key feature is the provision of two separate 0/12 V secondary windings. When connected correctly in parallel, the windings provide a nominal 12 V AC output. Parallel operation combines the available current contribution of the two windings while retaining the transformer's overall 400 VA rating. Matching winding voltages and correct polarity are essential because incorrect parallel connections can produce damaging circulating currents.

When connected correctly in series, the two secondary windings provide a nominal 24 V AC output. This configuration adds the voltages of the individual 12 V windings while retaining the overall transformer apparent power rating. Correct winding polarity and terminal identification are essential, as an incorrect series connection may result in voltage cancellation or an unsuitable output.

At the rated 400 VA capacity, the calculated nominal secondary current is approximately 33.33 A at 12 V AC with the windings connected in parallel, or 16.67 A at 24 V AC with the windings connected in series. These figures are calculated from the transformer apparent power rating and nominal output voltages rather than separately verified manufacturer current ratings. The 400 VA rating applies to the transformer as a whole and must not be interpreted as 400 VA independently available from each secondary winding.

The specified 8% voltage regulation is relevant when evaluating secondary voltage variation under changing load conditions. Actual output voltage depends on the primary supply, selected terminals, winding configuration and connected load. Equipment with narrow operating voltage tolerances should be checked for compatibility, particularly where control relays, contactor coils, solenoids or other inductive devices introduce changing loads and starting currents.

With Class E insulation, dimensions of 120 × 108 × 120 mm and a weight of 5.5 kg, the MV400P2S3 can be incorporated into appropriately engineered industrial control assemblies. Its EPH 3 or EPN 2 enclosure references assist with enclosure planning. Installers should provide suitable mechanical support, primary and secondary circuit protection, conductor sizing, ventilation and electrical clearances, following the manufacturer's instructions for both primary and secondary winding connections.

Typical Applications

  • Industrial control circuits requiring a nominal 12 V AC supply.
  • Industrial control circuits requiring a nominal 24 V AC supply.
  • Electrical control panels with compatible 380 V or 420 V primary supply arrangements.
  • Industrial machinery and OEM automation equipment.
  • Motor control panels requiring dedicated low-voltage AC control power.
  • Control relays and contactors with compatible AC coil voltages.
  • Industrial signalling and indication circuits.
  • Low-voltage AC solenoid and actuator circuits within the transformer rating.
  • Machinery electrical cabinets and control enclosures.
  • Industrial process control equipment with suitable AC loads.
  • Electrical panel building and automation system integration.
  • Control transformer replacement and maintenance projects.
  • Equipment requiring series-connected or parallel-connected transformer secondary windings.
  • Control circuit upgrades requiring a 400 VA multi-voltage transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer ETE
Rated Power (VA) 400 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 0/12V + 0/12V
Phase Single Phase
Product series MV Multi-Voltage Control Transformers
Manufacturer part number MV400P2S3
Product type Multi-voltage control transformer
Transformer configuration Single-phase
Rated apparent power 400 VA
Rated capacity 0.4 kVA
Primary terminals 20/0/380/420 V
Primary voltage terminal markings 380 V and 420 V
Primary adjustment tap 20 V
Primary connection requirement Confirm correct terminal connections with ETE
Number of secondary windings 2
Secondary winding 1 terminals 0/12 V
Secondary winding 2 terminals 0/12 V
Parallel secondary output 12 V AC
Series secondary output 24 V AC
Secondary connection arrangement 12 V parallel or 24 V series
Calculated secondary current at 12 V parallel Approximately 33.33 A at 400 VA
Calculated secondary current at 24 V series Approximately 16.67 A at 400 VA
Insulation class E
Voltage regulation 8%
Length 120 mm
Width 108 mm
Height 120 mm
Dimensions (L × W × H) 120 × 108 × 120 mm
Weight 5.5 kg
Enclosure reference EPH 3 or EPN 2
Product range ETE Stock Control Transformers
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV400P2S3 used for?

The ETE MV400P2S3 is a 400 VA single-phase multi-voltage control transformer used to provide a nominal 12 V AC or 24 V AC secondary supply for compatible industrial control circuits, machinery and automation equipment.

What is the power rating of the ETE MV400P2S3?

The transformer has a rated apparent power of 400 VA (0.4 kVA). This is the overall transformer rating and applies to the combined load on its secondary windings.

What primary terminals does the MV400P2S3 have?

The transformer features 20/0/380/420 V primary terminals. These include a 20 V adjustment tap, and the correct primary connection arrangement must be confirmed with ETE before installation.

What is the purpose of the 20 V primary adjustment tap?

The 20 V primary adjustment tap provides an additional connection facility within the primary winding arrangement. Its correct use and wiring configuration must be confirmed with ETE; the terminal markings alone should not be used to assume a particular adjustment connection.

What secondary voltages can the MV400P2S3 provide?

The transformer supports a nominal 12 V AC output with the secondary windings connected in parallel or a nominal 24 V AC output with the windings connected in series, using the manufacturer's specified wiring arrangements.

How many secondary windings does the MV400P2S3 have?

The MV400P2S3 has two secondary windings, each with 0/12 V terminals. The windings can be connected in the specified series or parallel configurations.

Can the MV400P2S3 provide 12 V AC in parallel?

Yes. The two secondary windings can be connected in parallel to provide a nominal 12 V AC output. Correct winding polarity and matching voltage connections are essential, and the total load must remain within the 400 VA rating.

Can the MV400P2S3 provide 24 V AC in series?

Yes. The two secondary windings can be connected in series to provide a nominal 24 V AC output. The correct series connection and winding polarity must be followed according to the manufacturer's instructions.

What is the calculated secondary current at 12 V?

At the rated 400 VA capacity and a nominal 12 V AC parallel output, the calculated current is approximately 33.33 A. This is a calculated value rather than a separately verified manufacturer current rating.

What is the calculated secondary current at 24 V?

At the rated 400 VA capacity and a nominal 24 V AC series output, the calculated current is approximately 16.67 A. This is a calculated value rather than a separately verified manufacturer current rating.

What does the 8% voltage regulation specification mean?

The MV400P2S3 has a specified 8% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should have suitable operating voltage tolerance.

What insulation class does the ETE MV400P2S3 use?

The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.

What are the dimensions and weight of the ETE MV400P2S3?

The transformer measures 120 × 108 × 120 mm (L × W × H) and weighs 5.5 kg. These details assist with electrical panel layout and mounting arrangements.

Which enclosure references are associated with the MV400P2S3?

The associated enclosure references are EPH 3 or EPN 2. The appropriate enclosure and its suitability for the installation should be confirmed before selection.

What should be checked before installing the ETE MV400P2S3?

Before installation, confirm the correct 20/0/380/420 V primary connections and the use of the 20 V adjustment tap with ETE. Select the required 12 V parallel or 24 V series secondary arrangement, follow the manufacturer's winding connection instructions, check the connected load against the 400 VA rating and provide suitable circuit protection, conductor sizing, mounting, ventilation and electrical clearances.

Trusted by Industrial Panel Builders and Automation Engineers

ETE MV multi-voltage control transformers provide a practical solution for industrial applications requiring flexible primary connections and configurable low-voltage AC outputs. With 20/0/380/420 V primary terminals, dual 0/12 V secondary windings, selectable 12 V parallel or 24 V series output, a 400 VA rating and Class E insulation, the MV400P2S3 offers electrical panel builders, machinery manufacturers and automation engineers a versatile transformer option for industrial control power.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...