ETE MV500P2S1 Multi-Voltage Control Transformer 500VA 20/0/380/420V to 0/55/110V

ETE MV500P2S1 Multi-Voltage Control Transformer 500VA 20/0/380/420V to 0/55/110V

ETE MV500P2S1 is a 500 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary connections, Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure compatibility.

SKU: MV500P2S1MPN: MV500P2S1
Price
List Price £99.10 ex VAT
Your Price (ex VAT)
£99.10
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £99.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£99.10

Why Choose the ETE MV500P2S1 500 VA Multi-Voltage Control Transformer?

The ETE MV500P2S1 is a 500 VA single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring selectable AC control voltages. Part of the ETE MV multi-voltage control transformer range, this model features 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, providing nominal 55 V AC or 110 V AC output connections for compatible industrial control equipment.

The MV500P2S1 combines a substantial 500 VA apparent power rating with a tapped secondary winding, making it a practical choice for control circuits with higher aggregate electrical loads. Its primary winding incorporates terminals marked 380 V and 420 V, together with a 20 V primary adjustment tap. The precise function and permitted connection combinations of this adjustment tap must be confirmed with ETE before installation.

The secondary winding features a 0/55/110 V terminal arrangement, allowing nominal 55 V AC or 110 V AC connections according to the intended control circuit. This flexibility is useful when specifying transformers for compatible contactors, electromagnetic relays, signalling devices, solenoids and other AC-operated industrial equipment.

Featuring Class E insulation and 8% voltage regulation, the ETE MV500P2S1 provides defined electrical characteristics for industrial transformer selection. Its dimensions of 120 × 120 × 120 mm and weight of 6.2 kg support integration into suitably designed electrical cabinets. The specified compatible enclosure references are ETE EPH 3 or EPN 2.

Key Advantages

  • 500 VA rated apparent power: Provides capacity for appropriately sized industrial control circuits and multiple compatible AC control devices.
  • Multi-voltage primary connections: Incorporates 20/0/380/420 V terminals for flexible industrial supply arrangements.
  • Selectable secondary output: Supports nominal 55 V AC or 110 V AC connections.
  • 20 V primary adjustment tap: Provides an additional winding connection, with the correct configuration to be confirmed with ETE.
  • Tapped secondary winding: Allows different nominal control voltage connections within one transformer model.
  • Class E insulation: Provides a defined insulation classification for industrial electrical applications.
  • 8% voltage regulation: Offers a specified regulation characteristic for evaluating secondary voltage variation under load.
  • Flexible control panel integration: Suitable for compatible machinery control and automation circuits.
  • Compact dimensions: Measures 120 × 120 × 120 mm.
  • Defined installation weight: Weighs 6.2 kg for mounting and enclosure planning.
  • Compatible enclosure options: Specified for ETE EPH 3 or EPN 2.
  • Industrial application versatility: Suitable for appropriately rated relays, contactors, signalling circuits and AC-operated actuators.
  • Established product range: Listed in the ETE stock control transformer range, March 2026.

Key Features

  • Manufacturer: ETE.
  • Manufacturer part number: MV500P2S1.
  • Product series: MV multi-voltage control transformers.
  • Transformer type: Single-phase industrial control transformer.
  • Rated apparent power: 500 VA.
  • Primary terminal arrangement: 20/0/380/420 V.
  • Primary voltage terminal markings: 380 V and 420 V.
  • Primary adjustment provision: 20 V tap; confirm connections with ETE.
  • Secondary terminal arrangement: 0/55/110 V.
  • Nominal secondary output options: 55 V AC or 110 V AC.
  • Calculated nominal secondary current at 110 V: Approximately 4.55 A.
  • 55 V tap loading: Subject to the manufacturer's permitted winding section current rating.
  • Insulation class: E.
  • Voltage regulation: 8%.
  • Length: 120 mm.
  • Width: 120 mm.
  • Height: 120 mm.
  • Weight: 6.2 kg.
  • Compatible enclosure references: EPH 3 or EPN 2.

Reliable 500 VA Control Power with Selectable 55 V or 110 V AC Outputs

The ETE MV500P2S1 is designed for industrial electrical installations where the available AC supply must be transformed to a suitable control voltage. Its 20/0/380/420 V primary arrangement and 0/55/110 V secondary winding provide flexibility for control panel builders and machinery manufacturers working with compatible industrial electrical systems.

The primary winding includes terminals marked 380 V and 420 V, together with a 20 V adjustment tap. This adjustment terminal should not be treated as a standalone 20 V supply connection. The exact permitted terminal combinations and intended adjustment function must be verified using ETE's approved connection information before the transformer is energised.

The secondary winding incorporates an intermediate 55 V tap and a full 110 V connection. This provides selectable nominal secondary voltages for compatible industrial control equipment. Where the transformer is being considered for a centre-tapped 110 V application, the intended connection arrangement and any centre-point earthing requirements must be checked against the manufacturer's documentation.

The 500 VA apparent power rating corresponds to a calculated nominal full-load current of approximately 4.55 A at 110 V AC. This is derived by dividing the transformer rating by the nominal full secondary voltage. The permitted current through the intermediate 55 V winding section has not been specified separately and must be confirmed before loading that tap. The full 500 VA rating should not automatically be assumed to be available independently from the 55 V connection.

The specified 8% voltage regulation is an important consideration when selecting control transformers for circuits containing electromagnetic loads. Contactors, relays and solenoids can have different apparent power demands during energisation and normal operation. Electrical designers should consider the total steady-state load, simultaneous switching requirements and the acceptable voltage range of connected equipment.

With Class E insulation, dimensions of 120 × 120 × 120 mm and a weight of 6.2 kg, the MV500P2S1 can be incorporated into appropriately designed industrial control cabinets. Its specified EPH 3 or EPN 2 enclosure references provide compatible housing options where additional physical protection is required.

The MV500P2S1 provides AC voltage transformation rather than regulated DC output. Equipment requiring DC control voltage will need suitable additional conversion components. Installation should account for correct primary tap selection, suitable circuit protection, conductor sizing, mechanical mounting, ventilation and protective earthing where applicable.

Typical Applications

  • Industrial electrical control panels requiring selectable 55 V AC or 110 V AC supplies.
  • Machinery control systems using compatible industrial primary voltage connections.
  • OEM machinery and electrical panel manufacturing.
  • Contactor and electromagnetic relay control circuits.
  • Motor starter panels and machine control systems.
  • Industrial signalling and indication circuits.
  • Compatible AC-operated solenoid valves and actuators.
  • Automation equipment requiring transformer-derived AC control power.
  • Packaging machinery and conveyor control systems.
  • Industrial process control installations.
  • Electrical maintenance and refurbishment projects.
  • Replacement of compatible 500 VA multi-voltage control transformers.

Technical Specifications

Tick the specs you need, then view products that match.

Brand ETE
Rated Power (VA) 500 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 0/55/110V
Phase Single Phase
Manufacturer part number MV500P2S1
Product family MV Multi-Voltage Control Transformers
Product category Industrial Control Transformers
Transformer configuration Tapped primary and secondary windings
Number of phases Single-phase
Rated apparent power 500 VA
Primary terminal arrangement 20/0/380/420 V
Primary voltage terminal markings 380 V and 420 V
Primary adjustment tap 20 V
Primary connection note Confirm the correct 20 V adjustment tap connections with ETE before energising.
Secondary terminal arrangement 0/55/110 V
Nominal secondary output options 55 V AC or 110 V AC
Calculated nominal full-load secondary current at 110 V Approximately 4.55 A
55 V secondary tap current rating Confirm with ETE before applying the full transformer apparent power to the intermediate tap.
Insulation class E
Voltage regulation 8%
Length 120 mm
Width 120 mm
Height 120 mm
Overall dimensions (L × W × H) 120 × 120 × 120 mm
Weight 6.2 kg
Compatible enclosure references EPH 3 or EPN 2
Typical installation Industrial electrical control panels and machinery cabinets
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV500P2S1 used for?

The ETE MV500P2S1 is a 500 VA single-phase multi-voltage control transformer designed to provide selectable 55 V AC or 110 V AC secondary connections for compatible industrial control equipment.

What are the primary terminals on the MV500P2S1?

The primary terminal markings are 20/0/380/420 V. The correct connection arrangement, particularly the function of the 20 V adjustment tap, must be confirmed with ETE.

What is the purpose of the 20 V primary adjustment tap?

The 20 V primary adjustment tap provides an additional winding connection. Its precise relationship to the 0, 380 V and 420 V terminals must be verified using ETE's approved connection information before installation.

Can the MV500P2S1 be connected to a 400 V AC supply?

The transformer has primary terminals marked 380 V and 420 V, together with a 20 V adjustment tap. The correct connection arrangement for a nominal 400 V AC supply must be confirmed with ETE rather than inferred from the terminal markings alone.

What secondary voltages does the MV500P2S1 provide?

The secondary terminals are marked 0/55/110 V, providing nominal 55 V AC or 110 V AC output connections when wired correctly.

Is the MV500P2S1 a centre-tapped 110 V transformer?

The 0/55/110 V secondary arrangement includes an intermediate 55 V tap on the 110 V winding. The suitability of this arrangement for a particular centre-tapped application, including any centre-point earthing requirements, must be confirmed from ETE's connection information.

What is the rated apparent power of the MV500P2S1?

The MV500P2S1 has a rated apparent power of 500 VA. The connected load must remain within the applicable transformer and winding ratings.

What is the calculated full-load current at 110 V?

At 500 VA and 110 V AC, the calculated nominal full-load secondary current is approximately 4.55 A.

Can the full 500 VA rating be drawn from the 55 V tap?

Not without confirmation. The transformer has a total rated apparent power of 500 VA, but the allowable current through the individual 55 V winding section has not been specified separately. The applicable tap loading limit should be confirmed with ETE.

Does the MV500P2S1 provide AC or DC output?

The transformer provides AC output. It does not incorporate a rectifier or regulated DC power supply.

What insulation class and voltage regulation does the MV500P2S1 have?

The transformer has Class E insulation and a specified 8% voltage regulation.

What are the dimensions and weight of the ETE MV500P2S1?

The transformer measures 120 mm long × 120 mm wide × 120 mm high and weighs 6.2 kg.

Which enclosures are compatible with the MV500P2S1?

The specified compatible enclosure references are ETE EPH 3 or EPN 2. Final enclosure selection should account for the installation environment, mounting requirements and ventilation.

Can the MV500P2S1 be used in industrial control panels?

Yes. Its 500 VA rating, selectable secondary voltage connections and compact construction make it suitable for appropriately designed industrial control panels using compatible AC control equipment.

Why is voltage regulation important when selecting this transformer?

The specified 8% voltage regulation indicates that secondary voltage changes with loading. Connected control equipment should have suitable operating voltage tolerances, particularly where electromagnetic devices produce high energisation demands.

Where can the correct primary and secondary connection diagrams be confirmed?

The correct wiring information should be obtained from ETE or its approved technical documentation. This is especially important when using the 20 V primary adjustment tap or configuring the secondary winding for a particular control circuit.

A Practical Choice for Industrial Control Panel Builders

The ETE MV500P2S1 combines a 500 VA rating with flexible primary connections and selectable 55 V or 110 V AC secondary outputs. Its Class E insulation, 8% voltage regulation and compact construction make it a practical component for industrial electrical panel builders, machinery manufacturers and maintenance engineers requiring adaptable AC control power.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...