Why Choose the ETE MV6250P2S2 6250 VA Multi-Voltage Control Transformer?
The ETE MV6250P2S2 is a high-capacity 6250 VA (6.25 kVA) single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring substantial AC voltage transformation capacity. Part of the ETE MV multi-voltage control transformer range, this model features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a tapped secondary output arrangement for compatible industrial electrical equipment.
With a rated apparent power of 6250 VA, the MV6250P2S2 is particularly suitable for larger industrial installations where multiple AC-operated devices or substantial connected loads require a higher-capacity control transformer. Its multi-voltage winding arrangement provides flexibility for electrical panel builders, machinery manufacturers and industrial maintenance engineers working with compatible primary supplies and secondary control voltage requirements.
The primary winding incorporates terminals marked 380 V and 420 V, together with additional terminals marked 20 V and 0 V. The secondary winding features terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The manufacturer's specified output arrangement is a tapped output according to the datasheet. The correct terminal combinations, particularly those involving the 10 V adjustment tap, must be confirmed with ETE before installation.
Featuring Class F insulation and 3% voltage regulation, the MV6250P2S2 provides defined electrical characteristics for demanding industrial transformer applications. Its dimensions of 245 × 250 × 230 mm and weight of 58 kg should be considered when planning electrical cabinet layouts, mounting arrangements and mechanical support.
The specified compatible enclosure reference is ETE EPN 7. Listed in the ETE Stock Control Transformer Range, March 2026, the MV6250P2S2 is a practical option for industrial installations requiring a substantial single-phase transformer with configurable AC output connections.
Key Advantages
- 6250 VA (6.25 kVA) rated capacity: Provides substantial apparent power for appropriately sized industrial AC control and auxiliary circuits.
- Multi-voltage primary arrangement: Features 20/0/380/420 V primary terminals for compatible industrial supply connections.
- Tapped secondary winding: Incorporates 10/0/220/240 V secondary terminals for manufacturer-defined output configurations.
- 220 V and 240 V secondary terminals: Supports compatible higher-voltage AC control and auxiliary power applications.
- 10 V secondary adjustment tap: Provides an additional winding connection, with the correct configuration to be confirmed with ETE.
- Class F insulation: Provides a defined insulation thermal classification for industrial transformer selection.
- 3% voltage regulation: Offers a specified regulation characteristic for evaluating secondary voltage variation under load.
- High-capacity control power: Suitable for appropriately designed installations containing multiple compatible AC electrical loads.
- Flexible industrial integration: Supports machinery control, automation, electrical distribution within equipment and auxiliary AC supply applications.
- Defined dimensions: Measures 245 × 250 × 230 mm for installation and enclosure planning.
- Defined installation weight: Weighs 58 kg, allowing mechanical support and handling requirements to be assessed.
- Compatible enclosure reference: ETE EPN 7.
- Industrial application versatility: Suitable for appropriately rated contactors, relays, AC-operated equipment and machinery auxiliary circuits.
- Established product range: Listed in the ETE stock control transformer range, March 2026.
Key Features
- Manufacturer: ETE.
- Manufacturer part number: MV6250P2S2.
- Product series: MV multi-voltage control transformers.
- Transformer type: Single-phase industrial control transformer.
- Rated apparent power: 6250 VA (6.25 kVA).
- Primary terminal arrangement: 20/0/380/420 V.
- Primary voltage terminal markings: 380 V and 420 V.
- Additional primary terminal: 20 V.
- Secondary terminal arrangement: 10/0/220/240 V.
- Secondary voltage terminal markings: 220 V and 240 V.
- Secondary adjustment tap: 10 V.
- Output configuration: Tapped output according to ETE's approved connection information.
- Connection precaution: Confirm the correct 10 V adjustment tap and associated terminal connections with ETE.
- Calculated current equivalent at 220 V: Approximately 28.41 A, based on the total 6250 VA rating.
- Calculated current equivalent at 240 V: Approximately 26.04 A, based on the total 6250 VA rating.
- Insulation class: F.
- Voltage regulation: 3%.
- Length: 245 mm.
- Width: 250 mm.
- Height: 230 mm.
- Weight: 58 kg.
- Compatible enclosure reference: EPN 7.
Reliable 6.25 kVA Tapped AC Control Power for Demanding Industrial Applications
The ETE MV6250P2S2 provides a high-capacity solution for industrial electrical installations requiring a transformer with multiple primary and secondary connection options. Its 20/0/380/420 V primary winding and 10/0/220/240 V secondary winding make it suitable for applications where a compatible industrial AC supply must be transformed to an appropriate AC control or auxiliary voltage.
The primary winding incorporates terminals marked 380 V and 420 V, together with additional terminals marked 20 V and 0 V. These markings identify the available winding connections but do not independently establish every permissible supply voltage combination. The exact primary terminal arrangement should be verified against ETE's approved wiring diagram before the transformer is energised.
The secondary winding features terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The manufacturer's specification describes the output as a tapped output, with the correct terminal configuration defined by the datasheet. The 10 V terminal should not be assumed to provide an independent 10 V output, and the relationship between the secondary terminals must be confirmed with ETE.
At the total rated apparent power of 6250 VA, the calculated current equivalents are approximately 28.41 A at 220 V and 26.04 A at 240 V. These figures are calculated by dividing the rated apparent power by the nominal secondary voltage. They are theoretical values for the respective voltage levels rather than independently verified current ratings for every tapped output configuration. The permitted winding and tap loading limits must be checked before finalising the connected load.
The specified 3% voltage regulation is relevant when selecting transformers for industrial circuits containing equipment with changing electrical loads. Contactors, relays, solenoids and other electromagnetic devices can draw greater apparent power during energisation than during normal operation. Electrical designers should assess the aggregate steady-state load, simultaneous switching demands and acceptable operating voltage range of connected equipment.
The MV6250P2S2 features Class F insulation, a recognised transformer insulation thermal classification. This provides a defined basis for insulation selection, although the transformer's permissible ambient temperature, operating duty and thermal installation conditions should be confirmed against the manufacturer's technical documentation.
With a rated capacity of 6.25 kVA, the MV6250P2S2 is particularly relevant to larger industrial installations containing multiple compatible AC electrical loads. Transformer selection should consider the total apparent power requirement, winding-specific current limits, starting demands and the suitability of the selected primary and secondary connections.
The transformer measures 245 × 250 × 230 mm and weighs 58 kg. Its substantial weight requires appropriate consideration of lifting, handling, secure mounting and mechanical support. The specified compatible enclosure reference is ETE EPN 7, with final installation arrangements dependent on the intended operating environment and ventilation requirements.
The MV6250P2S2 provides AC voltage transformation rather than regulated DC output. Equipment requiring DC control voltage will need suitable additional conversion components. Installation should account for correct primary and secondary terminal selection, appropriately rated circuit protection, conductor sizing, secure mounting, ventilation and protective earthing where applicable.
Typical Applications
- High-capacity industrial electrical control panels requiring tapped AC transformer outputs.
- Large machinery control systems using compatible industrial primary voltage connections.
- OEM machinery and industrial electrical panel manufacturing.
- Compatible 220 V AC and 240 V AC control circuits.
- Higher-capacity contactor and electromagnetic relay control systems.
- Industrial motor control and machine auxiliary circuits.
- Industrial signalling and indication circuits.
- Automation equipment requiring substantial transformer-derived AC power.
- Packaging machinery and conveyor control systems.
- Industrial process control installations.
- Electrical maintenance and refurbishment projects.