ETE MV750P2S2 Multi-Voltage Control Transformer 750VA 20/0/380/420V to 10/0/220/240V

ETE MV750P2S2 Multi-Voltage Control Transformer 750VA 20/0/380/420V to 10/0/220/240V

ETE MV750P2S2 is a 750 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, tapped 10/0/220/240 V secondary terminals requiring ETE confirmation of the 10 V adjustment connections, Class E insulation, 4% voltage regulation and an EPN 3 enclosure reference.

SKU: MV750P2S2MPN: MV750P2S2
Price
List Price £134.80 ex VAT
Your Price (ex VAT)
£134.80
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £134.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£134.80

Why Choose the ETE MV750P2S2 750 VA Multi-Voltage Control Transformer?

The ETE MV750P2S2 is a 750 VA single-phase multi-voltage control transformer designed for industrial electrical installations requiring selectable primary connections and a tapped secondary winding. Part of the ETE MV multi-voltage control transformer series, it features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a versatile solution for industrial control panels, machinery and automation equipment.

The transformer incorporates nominal 380 V and 420 V primary terminal selections, allowing integration into compatible industrial supply systems. Its secondary winding includes 220 V and 240 V terminal markings, together with a 10 V adjustment tap. The precise secondary output connection arrangement must follow the ETE datasheet, and the correct adjustment tap connections must be confirmed with ETE before installation.

With a rated capacity of 750 VA (0.75 kVA), the MV750P2S2 is suitable for supplying compatible AC control loads within its specified apparent power rating. Its 4% voltage regulation provides a useful specification for assessing secondary voltage variation between load conditions, while Class E insulation provides a defined thermal insulation classification.

Measuring 150 × 108 × 145 mm and weighing 7.6 kg, the ETE MV750P2S2 can be incorporated into appropriately designed industrial electrical assemblies. Its associated enclosure reference is EPN 3, supporting enclosure selection and control panel planning.

Key Advantages

  • 750 VA rated capacity: Provides dedicated AC power for compatible industrial control circuits and electrical equipment.
  • Multi-voltage primary arrangement: Features 20/0/380/420 V primary terminals for the manufacturer's specified connection configurations.
  • 380 V primary terminal selection: Supports compatible industrial electrical supply arrangements.
  • 420 V primary terminal selection: Provides an alternative nominal input connection for suitable installations.
  • Tapped secondary winding: Incorporates 10/0/220/240 V terminals for the output arrangements specified by ETE.
  • 220 V secondary terminal marking: Supports applications requiring a compatible nominal AC control voltage when connected as specified.
  • 240 V secondary terminal marking: Provides an additional nominal secondary voltage selection subject to the manufacturer's connection instructions.
  • 10 V adjustment tap: Offers an additional connection facility, with correct terminal connections requiring confirmation from ETE.
  • 4% voltage regulation: Provides a specified indication of secondary voltage variation under changing load conditions.
  • Class E insulation: Provides a defined thermal insulation classification.
  • Single-phase construction: Suitable for dedicated AC control voltage transformation.
  • Compact dimensions: The 150 × 108 × 145 mm format assists with electrical panel layout planning.
  • 7.6 kg weight: Enables suitable mechanical support and mounting arrangements to be specified.
  • EPN 3 enclosure reference: Assists with identifying the associated enclosure arrangement.
  • Industrial application flexibility: Suitable for appropriately engineered machinery, control panels and automation systems.

Key Features

  • Manufacturer: ETE.
  • Product series: MV Multi-Voltage Control Transformers.
  • Model: MV750P2S2.
  • Rated apparent power: 750 VA.
  • Rated capacity: 0.75 kVA.
  • Transformer configuration: Single-phase.
  • Primary terminal arrangement: 20/0/380/420 V.
  • Primary voltage terminal markings: 380 V and 420 V.
  • Secondary terminal arrangement: 10/0/220/240 V.
  • Secondary voltage terminal markings: 220 V and 240 V.
  • Adjustment tap: 10 V.
  • Secondary output connection: Tapped output according to the ETE datasheet.
  • Connection requirement: Confirm correct 10 V adjustment tap connections with ETE.
  • Insulation class: E.
  • Voltage regulation: 4%.
  • Length: 150 mm.
  • Width: 108 mm.
  • Height: 145 mm.
  • Weight: 7.6 kg.
  • Associated enclosure reference: EPN 3.

Reliable Multi-Voltage Control Power with Tapped Secondary Connections

The ETE MV750P2S2 is designed for industrial electrical installations requiring a dedicated control transformer with multiple voltage terminal selections. Its 20/0/380/420 V primary terminal arrangement includes nominal 380 V and 420 V terminal markings, allowing the appropriate input connection to be selected in accordance with ETE's instructions. The correct terminal arrangement should always be verified before the transformer is energised.

The secondary winding features 10/0/220/240 V terminal markings. These provide a tapped secondary arrangement incorporating nominal 220 V and 240 V positions together with a 10 V adjustment tap. However, the complete permissible output connection arrangements cannot be established from the terminal markings alone. ETE's datasheet must be followed, and the correct use of the 10 V adjustment tap must be confirmed with ETE.

At its rated 750 VA capacity, the calculated nominal secondary current is approximately 3.41 A at 220 V AC or 3.13 A at 240 V AC, assuming the corresponding output connection is approved by ETE. These figures are calculated from apparent power divided by nominal voltage and are not separately verified manufacturer current ratings. The transformer must not be loaded beyond its overall 750 VA rating or any additional winding and terminal limits specified by the manufacturer.

The specified 4% voltage regulation is relevant when assessing secondary voltage variation between load conditions. Actual output voltage depends on the incoming supply, selected primary and secondary connections and connected load. Control relays, contactor coils and other inductive equipment may introduce changing loads or short-duration inrush requirements, so both continuous apparent power and operating characteristics should be considered when selecting the transformer.

With Class E insulation, dimensions of 150 × 108 × 145 mm and a weight of 7.6 kg, the MV750P2S2 can be incorporated into appropriately engineered industrial control assemblies. Its EPN 3 enclosure reference assists with enclosure planning. Suitable mechanical support, circuit protection, conductor sizing, ventilation and electrical clearances should be provided in accordance with the manufacturer's installation instructions and applicable electrical requirements.

Typical Applications

  • Industrial control panels requiring a 750 VA single-phase control transformer.
  • Machinery control circuits supplied from compatible 380 V primary connections.
  • Industrial equipment using compatible 420 V primary connections.
  • Control circuits requiring a manufacturer-approved 220 V AC secondary output.
  • Control circuits requiring a manufacturer-approved 240 V AC secondary output.
  • OEM machinery and industrial automation systems.
  • Motor control panels requiring dedicated AC control power.
  • Control relays and contactors with compatible AC coil voltages.
  • Industrial signalling and indication circuits.
  • Electrical machinery with tapped secondary control voltage requirements.
  • Industrial process control equipment with suitable AC loads.
  • Electrical panel building and automation system integration.
  • Control transformer replacement and maintenance projects.
  • Industrial control circuit upgrades requiring a 750 VA multi-voltage transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer ETE
Rated Power (VA) 750 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 10/0/220/240V
Phase Single Phase
Product series MV Multi-Voltage Control Transformers
Manufacturer part number MV750P2S2
Product type Multi-voltage control transformer
Transformer configuration Single-phase
Rated apparent power 750 VA
Rated capacity 0.75 kVA
Primary terminals 20/0/380/420 V
Primary voltage terminal markings 380 V and 420 V
Secondary terminals 10/0/220/240 V
Secondary voltage terminal markings 220 V and 240 V
Adjustment tap 10 V
Secondary output connection Tapped output per ETE datasheet
Adjustment tap connection requirement Confirm correct terminal connections with ETE
Calculated nominal secondary current at 220 V Approximately 3.41 A at 750 VA, subject to confirmation of the correct output connection
Calculated nominal secondary current at 240 V Approximately 3.13 A at 750 VA, subject to confirmation of the correct output connection
Calculated ideal primary current at 380 V Approximately 1.97 A at 750 VA, excluding transformer losses and magnetising current
Calculated ideal primary current at 420 V Approximately 1.79 A at 750 VA, excluding transformer losses and magnetising current
Insulation class E
Voltage regulation 4%
Length 150 mm
Width 108 mm
Height 145 mm
Dimensions (L × W × H) 150 × 108 × 145 mm
Weight 7.6 kg
Enclosure reference EPN 3
Product range ETE Stock Control Transformers
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV750P2S2 used for?

The ETE MV750P2S2 is a 750 VA single-phase multi-voltage control transformer designed to supply compatible industrial control circuits, machinery and automation equipment using its specified primary and tapped secondary connections.

What is the power rating of the ETE MV750P2S2?

The transformer has a rated apparent power of 750 VA (0.75 kVA). Connected loads must remain within this rating and any additional manufacturer-specified winding or terminal limits.

What primary terminals does the MV750P2S2 have?

The transformer features 20/0/380/420 V primary terminals, including nominal 380 V and 420 V terminal markings. The correct primary connection must follow ETE's instructions.

What secondary terminals does the MV750P2S2 have?

The transformer has 10/0/220/240 V secondary terminals, incorporating 220 V and 240 V terminal markings together with a 10 V adjustment tap.

Can the MV750P2S2 provide 220 V AC?

The secondary winding includes a 220 V terminal marking. The correct output connection arrangement must be established from the ETE datasheet before using the transformer to supply a nominal 220 V AC load.

Can the MV750P2S2 provide 240 V AC?

The secondary winding includes a 240 V terminal marking. The correct output connection arrangement must be established from the ETE datasheet before using the transformer to supply a nominal 240 V AC load.

What is the purpose of the 10 V adjustment tap?

The 10 V adjustment tap provides an additional connection facility within the tapped winding arrangement. Its correct use and terminal connections must be confirmed with ETE; the terminal markings alone should not be used to assume a particular adjustment configuration.

How should the secondary output be connected?

The secondary output must be connected according to the ETE datasheet. The supplied specification identifies a tapped output arrangement, and ETE should be consulted to confirm the correct terminal connections, particularly those involving the 10 V adjustment tap.

What is the calculated secondary current at 220 V?

At the rated 750 VA capacity and a nominal 220 V AC output, the calculated current is approximately 3.41 A. This is a theoretical calculation, not a separately verified manufacturer current rating, and assumes ETE confirms the corresponding output connection.

What is the calculated secondary current at 240 V?

At the rated 750 VA capacity and a nominal 240 V AC output, the calculated current is approximately 3.13 A. This is a theoretical calculation, not a separately verified manufacturer current rating, and assumes ETE confirms the corresponding output connection.

What does the 4% voltage regulation specification mean?

The MV750P2S2 has a specified 4% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should have suitable operating voltage tolerance.

What insulation class does the ETE MV750P2S2 use?

The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.

What are the dimensions and weight of the ETE MV750P2S2?

The transformer measures 150 × 108 × 145 mm (L × W × H) and weighs 7.6 kg. These details assist with electrical panel layout, mechanical support and installation planning.

Which enclosure reference is associated with the MV750P2S2?

The associated enclosure reference is EPN 3. The enclosure arrangement and its suitability for the intended installation should be confirmed before selection.

What should be checked before installing the ETE MV750P2S2?

Before installation, confirm the correct 20/0/380/420 V primary connections and the 10/0/220/240 V secondary connections. The correct use of the 10 V adjustment tap must be confirmed with ETE. Check the connected load against the 750 VA rating and provide suitable circuit protection, conductor sizing, mounting, ventilation and electrical clearances.

Trusted by Industrial Panel Builders and Automation Engineers

ETE MV multi-voltage control transformers offer a practical solution for industrial electrical applications requiring selectable primary connections and tapped secondary outputs. With 20/0/380/420 V primary terminals, 10/0/220/240 V secondary terminals, a 750 VA rating, Class E insulation and 4% voltage regulation, the MV750P2S2 provides electrical panel builders, machinery manufacturers and automation engineers with a versatile option for industrial control power, subject to confirmation of the correct adjustment tap connections with ETE.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...