Why Choose the ETE WV1000P7S7 1000 VA Wide-Input-Voltage Control Transformer?
The ETE WV1000P7S7 is a versatile 1000 VA (1 kVA) single-phase wide-input-voltage control transformer designed to provide dependable low-voltage AC power for industrial control circuits, electrical panels and automation equipment. Part of the ETE WV wide-input-voltage control transformer series, it offers multiple primary voltage selections and configurable secondary windings for electrical panel builders, OEM machinery manufacturers and industrial automation engineers.
Featuring 0/380/400/420/440/460/480 V primary terminals, the WV1000P7S7 supports six nominal industrial supply voltages through dedicated primary winding taps. Its two 0/24 V secondary windings can be connected in parallel to provide 24 V AC or in series to provide 48 V AC. This flexible winding arrangement makes the transformer suitable for installations requiring different low-voltage AC control supplies without changing the transformer model.
With a rated apparent power of 1000 VA, Class E insulation and 4% voltage regulation, the ETE WV1000P7S7 provides a practical solution for industrial control power distribution. Its dimensions of 150 × 125 × 145 mm and weight of 9.8 kg allow integration into appropriately designed electrical control panels. The specified enclosure reference is EPN 3.
Key Advantages
- 1000 VA (1 kVA) rated capacity provides a substantial power supply for industrial control equipment.
- Wide primary voltage selection from 380 V to 480 V AC accommodates multiple industrial electrical supply systems.
- Six dedicated primary voltage taps allow selection of the appropriate nominal input voltage.
- Dual 0/24 V secondary windings offer flexible output configurations.
- 24 V AC parallel output supports compatible low-voltage control circuits.
- 48 V AC series output provides an alternative voltage for compatible industrial equipment.
- 4% voltage regulation helps limit secondary voltage variation between no-load and rated-load conditions.
- Class E insulation provides a defined thermal insulation classification.
- Single-phase construction is suitable for dedicated AC control power transformation.
- Practical 150 × 125 × 145 mm dimensions support integration into industrial electrical cabinets.
- EPN 3 enclosure reference assists with planning a compatible enclosed installation.
- Multiple primary taps and configurable secondary windings can simplify transformer standardisation across compatible machinery and control panels.
Key Features
- ETE WV wide-input-voltage control transformer series.
- 1000 VA rated apparent power.
- 1 kVA nominal transformer capacity.
- Single-phase transformer configuration.
- Primary terminals: 0/380/400/420/440/460/480 V.
- Primary voltage options: 380, 400, 420, 440, 460 and 480 V AC.
- First secondary winding: 0/24 V.
- Second secondary winding: 0/24 V.
- Parallel secondary connection: 24 V AC.
- Series secondary connection: 48 V AC.
- Dual secondary winding design for adaptable control voltage requirements.
- Voltage regulation: 4%.
- Insulation class: E.
- Length: 150 mm.
- Width: 125 mm.
- Height: 145 mm.
- Weight: 9.8 kg.
- Enclosure reference: EPN 3.
- Designed for industrial control circuits requiring flexible primary supply selection and 24 V or 48 V AC output.
Reliable 24 V and 48 V AC Control Power for Industrial Automation
Industrial control transformers convert an available AC supply voltage into a suitable secondary voltage for electrical control circuits and connected equipment. The ETE WV1000P7S7 provides a flexible solution for installations using nominal primary voltages of 380, 400, 420, 440, 460 or 480 V AC. Selecting the appropriate primary terminal allows the transformer to accommodate the specified industrial supply without requiring a different transformer model for each listed voltage.
The transformer's two 0/24 V secondary windings allow different output arrangements. When correctly connected in parallel, they provide a nominal 24 V AC output, with the load shared between the windings. Alternatively, a correct series connection provides a nominal 48 V AC output. The transformer's total rated capacity remains 1000 VA in either configuration. Parallel connections must observe correct winding polarity, while series connections must follow the manufacturer's approved terminal arrangement.
The specified 4% voltage regulation is an important consideration when selecting control devices that require a relatively consistent AC supply. At its rated capacity, the transformer offers calculated nominal output currents of approximately 41.67 A at 24 V or 20.83 A at 48 V, subject to the manufacturer's winding ratings and installation requirements. Correct primary tap selection, secondary wiring, protective devices, ventilation and mechanical mounting are essential for dependable operation.
Typical Applications
- Industrial electrical control panels and automation cabinets.
- 24 V AC control power distribution systems.
- 48 V AC industrial control circuits.
- Industrial relays, contactors and control devices requiring AC supplies.
- Motor control panels and machinery electrical cabinets.
- Industrial signalling and indication equipment.
- Factory automation and manufacturing machinery.
- OEM equipment operating from 380–480 V AC primary supplies.
- Industrial process control systems.
- Electrical panel building and control system integration.
- Low-voltage AC supplies for compatible industrial actuators and control equipment.