ETE WV750P7S8 Wide Input Voltage Control Transformer 750VA 0/380/400/420/440/460/480V to 0/110/120V + 0/110/120V

ETE WV750P7S8 Wide Input Voltage Control Transformer 750VA 0/380/400/420/440/460/480V to 0/110/120V + 0/110/120V

ETE WV750P7S8 is a 750 VA single-phase wide-input-voltage control transformer with 0/380/400/420/440/460/480 V primary terminals, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 4% voltage regulation.

SKU: WV750P7S8MPN: WV750P7S8
Price
List Price £140.40 ex VAT
Your Price (ex VAT)
£140.40
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £140.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£140.40

Why Choose the ETE WV750P7S8 Wide-Input-Voltage Control Transformer?

The ETE WV750P7S8 is a versatile 750 VA single-phase wide-input-voltage control transformer designed to provide dependable AC voltage transformation and electrical isolation for industrial machinery, electrical control panels and automation systems. Part of the ETE WV stock control transformer range, it combines multiple primary voltage connections with configurable secondary windings, making it a practical choice for control panel builders, OEM machine manufacturers and industrial maintenance engineers.

The WV750P7S8 features primary terminals marked 0/380/400/420/440/460/480 V, providing six nominal input voltage options for industrial electrical installations. Its dual 0/110/120 V secondary windings can be connected in parallel for 110 V or 120 V AC output, or in series for 220 V or 240 V AC output. This flexible arrangement allows one transformer model to accommodate several common industrial control voltage requirements.

With a rated capacity of 750 VA, Class E insulation and 4% voltage regulation, the ETE WV750P7S8 provides substantial control power capacity with relatively low specified voltage regulation. Measuring 150 × 108 × 145 mm and weighing 7.6 kg, it is suitable for integration into appropriately designed industrial electrical equipment, with an associated EPN 3 enclosure reference.

Key Advantages

  • 750 VA rated apparent power for industrial control and auxiliary AC circuits.
  • Wide-input-voltage design with nominal primary connections from 380 V to 480 V AC.
  • Six selectable primary voltage connections for compatibility with different industrial electrical supplies.
  • Dual tapped secondary windings with 110 V and 120 V connections.
  • 110 V or 120 V AC parallel output for compatible industrial control equipment.
  • 220 V or 240 V AC series output for higher-voltage auxiliary circuits.
  • 4% voltage regulation to help limit secondary voltage variation between no-load and rated-load conditions.
  • Class E insulation for industrial transformer applications.
  • Provides electrical isolation between primary and secondary windings.
  • 750 VA total capacity for one or more compatible industrial control loads.
  • Practical 150 × 108 × 145 mm dimensions for control cabinet integration.
  • Associated EPN 3 enclosure reference.

Key Features

  • ETE WV wide-input-voltage control transformer series.
  • Single-phase transformer construction.
  • 750 VA total rated apparent power.
  • Primary terminal markings: 0/380/400/420/440/460/480 V.
  • Nominal primary connections: 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC.
  • Secondary terminal markings: 0/110/120 V + 0/110/120 V.
  • Secondary arrangement: Two tapped 110/120 V AC windings.
  • Parallel output: 110 V or 120 V AC.
  • Series output: 220 V or 240 V AC.
  • Insulation class: E.
  • Voltage regulation: 4%.
  • Electrical isolation between primary and secondary circuits.
  • Suitable for dedicated industrial AC control supplies.
  • Dimensions: 150 × 108 × 145 mm.
  • Weight: 7.6 kg.
  • Enclosure reference: EPN 3.

Flexible 110 V, 120 V, 220 V and 240 V AC Control Power for Industrial Automation

The ETE WV750P7S8 transforms a selected industrial AC input voltage into a secondary supply suitable for compatible control equipment. Its six nominal primary voltage connections support installations using 380 V, 400 V, 420 V, 440 V, 460 V or 480 V AC supplies. This flexibility can simplify transformer selection across machinery and electrical installations with different nominal supply voltages, provided the correct primary terminal is selected.

On the secondary side, the transformer incorporates two separate windings, each marked 0/110/120 V. When correctly connected in parallel, corresponding winding taps provide a 110 V or 120 V AC supply. When connected in an additive series arrangement, they provide 220 V or 240 V AC. Parallel connections require matching voltage taps and winding polarity, while series connections must use the correct additive polarity arrangement. All connections must follow ETE's terminal identification and wiring instructions.

The transformer's 750 VA capacity is the total rated apparent power, not a separate 750 VA allowance for each secondary winding. This capacity can support one or more compatible control loads, provided their combined operating and starting demands remain within the permitted transformer and winding ratings. Its specified 4% voltage regulation should be considered when selecting connected equipment, particularly where voltage tolerance is important.

With Class E insulation, dimensions of 150 × 108 × 145 mm and a 7.6 kg weight, the WV750P7S8 is suited to appropriately supported industrial control panel installations. The associated EPN 3 enclosure reference identifies the manufacturer's enclosure option. Installation design should account for adequate mechanical support, ventilation, electrical protection, earthing and safe access to terminals.

Typical Applications

  • 110 V AC industrial control circuits.
  • 120 V AC machinery control supplies.
  • 220 V AC auxiliary electrical circuits.
  • 240 V AC industrial control equipment.
  • Industrial machinery control panels and electrical cabinets.
  • Contactor and relay coil supply circuits.
  • Industrial motor starter and switching control systems.
  • Machine tools and manufacturing equipment.
  • Conveyor and material handling systems.
  • Packaging and processing machinery.
  • Industrial signalling and auxiliary electrical equipment.
  • OEM machinery and factory automation installations.
  • Electrical control panel manufacturing and refurbishment.
  • Compatible transformer replacement and machinery upgrade projects.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer ETE
Rated Power (VA) 750 VA
Primary Voltage 0/380/400/420/440/460/480V
Secondary Voltage 0/110/120V + 0/110/120V
Phase Single Phase
Product range WV Wide-Input-Voltage Stock Control Transformers
Model / SKU WV750P7S8
Product type Wide-input-voltage industrial control transformer
Phase configuration Single-phase
Rated apparent power 750 VA
Primary terminals 0/380/400/420/440/460/480 V
Nominal primary voltage options 380/400/420/440/460/480 V AC
Number of nominal primary voltage options 6
Secondary terminals 0/110/120 V + 0/110/120 V
Secondary winding configuration Dual tapped 110/120 V AC windings
Parallel output connection 110 V or 120 V AC
Series output connection 220 V or 240 V AC
Total transformer capacity 750 VA
Insulation class E
Voltage regulation 4%
Length 150 mm
Width 108 mm
Height 145 mm
Dimensions (L × W × H) 150 × 108 × 145 mm
Weight 7.6 kg
Enclosure reference EPN 3
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE WV750P7S8 used for?

The ETE WV750P7S8 is a 750 VA single-phase wide-input-voltage control transformer designed to provide isolated AC supplies for industrial machinery, control panels and compatible automation equipment. Its secondary windings support 110 V, 120 V, 220 V or 240 V AC output configurations.

What is the power rating of the ETE WV750P7S8?

The transformer has a total rated apparent power of 750 VA. This is the overall transformer capacity and must not be interpreted as 750 VA available independently from each secondary winding.

What primary input voltages does the WV750P7S8 support?

Its primary terminals are marked 0/380/400/420/440/460/480 V, providing nominal input voltage options of 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC.

What secondary output voltages are available?

The transformer has dual 0/110/120 V secondary windings. They can be connected in parallel for 110 V or 120 V AC, or in series for 220 V or 240 V AC, using the appropriate winding connections.

How are the secondary windings connected for parallel or series output?

For 110 V or 120 V AC, the corresponding secondary taps are connected in parallel with matching polarity. For 220 V or 240 V AC, the corresponding windings are connected in series with additive polarity. Connections must follow ETE's terminal identification and wiring instructions.

What insulation class does the ETE WV750P7S8 have?

The transformer has Class E insulation, providing a defined thermal insulation classification for operation within the manufacturer's specified limits.

What is the voltage regulation of the WV750P7S8?

The ETE WV750P7S8 has 4% voltage regulation. This describes the specified variation in secondary voltage between no-load and rated-load conditions and should be considered when selecting connected control equipment.

What are the dimensions and weight of the WV750P7S8?

The transformer measures 150 × 108 × 145 mm (length × width × height) and weighs 7.6 kg.

Which enclosure is associated with the ETE WV750P7S8?

The specified enclosure reference is EPN 3. The installation should provide suitable mounting support, ventilation, electrical protection and access for wiring and maintenance.

Can the WV750P7S8 supply multiple industrial control devices?

Yes. Its 750 VA total rated capacity can support multiple compatible devices, provided their combined apparent power, starting demands and operating requirements remain within the transformer's overall and individual winding limits.

Is the WV750P7S8 suitable for a 400 V AC primary supply?

Yes. The transformer includes a nominal 400 V AC primary connection, alongside 380 V, 420 V, 440 V, 460 V and 480 V AC options. The correct primary terminal must be selected and wired according to the manufacturer's instructions.

Trusted by Industrial Control Panel Builders and Engineers

The ETE WV750P7S8 combines 750 VA capacity, six nominal primary voltage options and configurable dual 110/120 V secondary windings in a robust industrial control transformer. With 110/120 V parallel or 220/240 V series output, Class E insulation and 4% voltage regulation, it provides a flexible solution for compatible industrial control and auxiliary AC power applications.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...