Frequently Asked Questions
What is the ETE XMS100P5S6 used for?
The ETE XMS100P5S6 is a 100 VA Class II safety/isolating transformer designed to provide a nominal 24 V AC supply from a 415 V AC input for compatible industrial control equipment.
What are the primary and secondary voltages?
The transformer has 0/415 V primary terminals and 0/24 V secondary terminals, providing a nominal 24 V AC output from a 415 V AC supply.
What does Class II mean?
Class II means the transformer incorporates a protective insulation arrangement that does not rely on a protective earth connection for protection against electric shock.
What is the power rating and calculated output current?
The transformer is rated at 100 VA, corresponding to approximately 4.17 A at 24 V AC under nominal full-load conditions.
Can the ETE XMS100P5S6 be DIN rail mounted?
Yes. The transformer supports DIN rail or chassis mounting for flexible installation within suitable electrical control panels.
What insulation class does the transformer use?
The ETE XMS100P5S6 incorporates Class F insulation, a thermal insulation classification associated with a temperature limit of 155 °C.
What are its dimensions and weight?
The transformer measures 90 × 106 × 96 mm and weighs 2.2 kg.
Does the ETE XMS100P5S6 have an enclosure?
Yes. It features an integral moulded housing as part of its Class II enclosed safety/isolating transformer construction.
Trusted by Industrial Electrical Engineers and Panel Builders
ETE XMS Class II enclosed safety/isolating transformers offer dependable isolated control power for industrial electrical installations. The XMS100P5S6 combines a 100 VA rating, 415 V AC primary input, 24 V AC output, Class F insulation and flexible DIN rail or chassis mounting for practical industrial control applications.
Why Choose the ETE XMS150P4S6 Class II Safety/Isolating Transformer?
The ETE XMS150P4S6 is a reliable 150 VA single-phase Class II enclosed safety/isolating transformer designed to convert a nominal 240 V AC primary supply into a 24 V AC secondary output. As part of the ETE XMS Class II transformer series, it provides isolated low-voltage AC power for industrial electrical control panels, machinery and automation systems.
The transformer features 0/240 V primary terminals and 0/24 V secondary terminals, providing a straightforward connection arrangement for compatible industrial electrical supplies. Its Class II protective insulation provides protection against electric shock without relying on a protective earth connection, while the integral moulded housing offers an enclosed construction.
With a rated apparent power of 150 VA, Class F insulation and flexible DIN rail or chassis mounting, the ETE XMS150P4S6 is suitable for supplying compatible 24 V AC relays, contactors and auxiliary control devices. Its dimensions of 102 × 115.5 × 106 mm and weight of 3 kg support installation within suitably designed industrial electrical cabinets.
Key Advantages
- Reliable Class II enclosed safety/isolating transformer for industrial applications.
- 150 VA rated capacity suitable for low-voltage control power requirements.
- 240 V AC primary input for compatible electrical supplies.
- 24 V AC secondary output for industrial control and automation equipment.
- Class II protective insulation provides electrical protection without reliance on protective earthing.
- Class F insulation supports dependable thermal performance.
- Integral moulded housing provides an enclosed transformer construction.
- DIN rail or chassis mounting allows flexible installation.
- Separate primary and secondary windings provide galvanic isolation.
- Compact construction suitable for industrial control cabinets.
Key Features
- ETE XMS Class II enclosed transformer series.
- 150 VA rated apparent power.
- Single-phase transformer construction.
- 0/240 V primary terminals.
- 240 V AC nominal primary input.
- 0/24 V secondary terminals.
- 24 V AC nominal secondary output.
- Class II safety/isolating construction.
- Class F insulation system.
- Integral moulded housing.
- DIN rail or chassis mounting.
- Calculated nominal full-load secondary current of 6.25 A.
- 102 × 115.5 × 106 mm dimensions.
- 3 kg transformer weight.
Technical Specifications
- Manufacturer: ETE
- Series: XMS Class II Enclosed Safety/Isolating Transformers
- Model: XMS150P4S6
- Product type: Enclosed safety/isolating transformer
- Number of phases: Single-phase
- Rated apparent power: 150 VA
- Primary terminals: 0/240 V
- Nominal primary voltage: 240 V AC
- Secondary terminals: 0/24 V
- Output connection: 24 V
- Nominal secondary voltage: 24 V AC
- Calculated nominal full-load secondary current: 6.25 A
- Electrical protection class: Class II
- Insulation class: Class F
- Enclosure reference: Integral moulded housing
- Mounting type: DIN rail or chassis mounting
- Length: 102 mm
- Width: 115.5 mm
- Height: 106 mm
- Dimensions (L × W × H): 102 × 115.5 × 106 mm
- Weight: 3 kg
- Product range: ETE Stock Control Transformer Range
- Reference: ETE Price List March 2026
Dependable 24 V AC Power for Industrial Control Circuits
The ETE XMS150P4S6 uses electromagnetic induction to transfer electrical energy between its primary and secondary windings. When connected to its specified 240 V AC primary supply, it provides a nominal 24 V AC secondary output for compatible low-voltage electrical equipment.
The transformer has a rated apparent power of 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC. This makes it suitable for industrial control relays, contactor coils, signalling devices and other compatible equipment, provided the total connected load remains within the transformer's rated capacity.
The Class II construction incorporates protective insulation measures that do not depend on a protective earth connection. This provides an important electrical safety characteristic for installations requiring Class II equipment, while appropriate circuit protection and installation practices remain essential.
The Class F insulation system, integral moulded housing and flexible mounting options make the XMS150P4S6 a practical choice for industrial panel builders. Its DIN rail or chassis mounting capability allows straightforward integration into suitable electrical cabinets and machinery enclosures.
Typical Applications
- Industrial electrical control panels requiring 24 V AC.
- Machinery control systems supplied from 240 V AC.
- 24 V AC relays and contactor coils.
- Industrial automation and auxiliary control circuits.
- Electrical signalling and monitoring equipment.
- Manufacturing and processing machinery.
- Building services equipment with compatible 24 V AC controls.
- OEM machinery and electrical panel building.
Frequently Asked Questions
What is the ETE XMS150P4S6 used for?
The ETE XMS150P4S6 is a 150 VA Class II enclosed safety/isolating transformer used to provide 24 V AC power from a 240 V AC input for compatible industrial control equipment.
What are the input and output voltages?
The transformer has 0/240 V primary terminals and 0/24 V secondary terminals, providing a nominal 24 V AC output from a 240 V AC supply.
What is the power rating and secondary current?
The transformer is rated at 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC.
What does Class II construction mean?
Class II construction means the transformer uses a protective insulation arrangement that does not rely on a protective earth connection for protection against electric shock.
Can the ETE XMS150P4S6 be mounted on a DIN rail?
Yes. The transformer supports DIN rail or chassis mounting for installation within suitable electrical cabinets and control panels.
What insulation class does the transformer use?
The ETE XMS150P4S6 uses Class F insulation, a thermal insulation classification associated with a temperature limit of 155 °C.
What are the dimensions and weight?
The transformer measures 102 × 115.5 × 106 mm and weighs 3 kg.
Does the ETE XMS150P4S6 have an enclosure?
Yes. It features an integral moulded housing as part of its enclosed Class II safety/isolating transformer construction.
Trusted by Industrial Electrical Engineers and Panel Builders
ETE XMS Class II enclosed safety/isolating transformers provide dependable isolated low-voltage power for industrial control systems. The XMS150P4S6 combines a 150 VA rating, 240 V AC primary input, 24 V AC secondary output, Class F insulation and flexible mounting for practical electrical panel installations.
Why Choose the ETE MV300P2S3 Multi-Voltage Control Transformer?
The ETE MV300P2S3 is a versatile 300 VA single-phase multi-voltage control transformer designed to provide flexible low-voltage AC power for industrial control circuits, machinery and automation systems. Part of the ETE MV multi-voltage transformer series, it features a multi-terminal primary winding and two separate secondary windings that can be configured to provide a nominal 12 V AC or 24 V AC output.
The transformer features 20/0/380/420 V primary terminals and 0/12 V + 0/12 V secondary terminals. The secondary windings can be connected in parallel for a nominal 12 V AC output or in series for a nominal 24 V AC output, following the correct winding polarity and manufacturer's connection instructions.
With a rated apparent power of 300 VA, Class E insulation and specified 8% voltage regulation, the ETE MV300P2S3 is suitable for a range of industrial control power applications. Its dimensions of 120 × 100 × 120 mm, weight of 4.7 kg and specified EPH 3 or EPN 2 enclosure references support integration into industrial electrical cabinets. The transformer also incorporates a 20 V primary adjustment tap, and its correct connections must be confirmed with ETE.
Key Advantages
- Versatile 300 VA multi-voltage control transformer for industrial applications.
- 20/0/380/420 V primary terminal arrangement provides flexible supply configuration.
- Dual 12 V secondary windings allow configurable low-voltage outputs.
- 12 V AC parallel or 24 V AC series output supports different control circuit requirements.
- 20 V primary adjustment tap for manufacturer-specified connection arrangements.
- Class E insulation provides dependable thermal insulation performance.
- 8% voltage regulation supports predictable secondary voltage behaviour.
- 300 VA capacity supports suitable industrial control loads.
- Separate primary and secondary windings provide galvanic isolation.
- EPH 3 or EPN 2 enclosure references offer protective enclosure options.
Key Features
- ETE MV multi-voltage control transformer series.
- 300 VA rated apparent power.
- Single-phase transformer construction.
- 20/0/380/420 V primary terminals.
- 20 V primary adjustment tap; confirm connections with ETE.
- 0/12 V + 0/12 V secondary terminals.
- Two 12 V secondary windings.
- 12 V AC parallel output configuration.
- 24 V AC series output configuration.
- Class E insulation system.
- 8% voltage regulation.
- Calculated nominal full-load current of 12.5 A at 24 V AC.
- EPH 3 or EPN 2 enclosure references.
- 120 × 100 × 120 mm dimensions.
- 4.7 kg transformer weight.
Technical Specifications
- Manufacturer: ETE
- Series: MV Multi-Voltage Control Transformers
- Model: MV300P2S3
- Product type: Multi-voltage control transformer
- Number of phases: Single-phase
- Rated apparent power: 300 VA
- Primary terminals: 20/0/380/420 V
- Primary adjustment tap: 20 V; confirm connections with ETE
- Secondary terminals: 0/12 V + 0/12 V
- Secondary winding arrangement: Two 12 V windings
- Output connection: 12 V parallel or 24 V series
- Nominal secondary output options: 12 V AC or 24 V AC
- Calculated nominal full-load current at 12 V: 25 A total at 300 VA
- Calculated nominal full-load current at 24 V: 12.5 A at 300 VA
- Insulation class: Class E
- Voltage regulation: 8%
- Enclosure reference: EPH 3 or EPN 2
- Length: 120 mm
- Width: 100 mm
- Height: 120 mm
- Dimensions (L × W × H): 120 × 100 × 120 mm
- Weight: 4.7 kg
- Product range: ETE Stock Control Transformer Range
- Reference: ETE Price List March 2026
Flexible 12 V and 24 V AC Power for Industrial Automation
The ETE MV300P2S3 uses electromagnetic induction to transfer electrical power between its primary and secondary windings. Its multi-terminal primary arrangement provides the specified voltage connection options, while the two separate 12 V secondary windings enable configurable low-voltage AC outputs.
When correctly connected in parallel, the secondary windings provide a nominal 12 V AC output. When correctly connected in series, they provide a nominal 24 V AC output. Correct winding polarity is essential, particularly for parallel operation, to prevent circulating currents or incorrect output voltages.
The transformer's 300 VA rating corresponds to a calculated nominal full-load output current of 25 A at 12 V AC or 12.5 A at 24 V AC, assuming the full rated capacity is available in the selected configuration. The actual permissible winding currents must comply with the manufacturer's connection and loading instructions.
The primary includes a 20 V adjustment tap as part of the 20/0/380/420 V terminal arrangement. The correct primary connections must be confirmed with ETE before energising the transformer. This is particularly important when selecting a primary configuration for an industrial electrical supply.
The Class E insulation system, specified 8% voltage regulation and compact industrial construction make the MV300P2S3 suitable for control panels and machinery requiring configurable low-voltage AC power.
Typical Applications
- Industrial control panels requiring 12 V AC or 24 V AC.
- Machinery control circuits and automation equipment.
- 12 V AC and 24 V AC relays and contactors.
- Industrial signalling and indication systems.
- Auxiliary low-voltage electrical control circuits.
- Manufacturing and processing machinery.
- Electrical cabinets requiring configurable transformer outputs.
- OEM machinery and electrical panel building.
Frequently Asked Questions
What is the ETE MV300P2S3 used for?
The ETE MV300P2S3 is a 300 VA single-phase multi-voltage control transformer used to supply compatible industrial control equipment with 12 V AC or 24 V AC.
What primary terminals does the ETE MV300P2S3 have?
The transformer features 20/0/380/420 V primary terminals, including a 20 V adjustment tap. Correct connections must be confirmed with ETE.
Can the ETE MV300P2S3 provide 12 V and 24 V AC?
Yes. Its two 12 V secondary windings can be connected in parallel for 12 V AC or in series for 24 V AC, following the correct manufacturer-approved connections.
What is the power rating of the transformer?
The ETE MV300P2S3 has a rated apparent power of 300 VA.
What is the calculated secondary current?
At the full 300 VA rating, the calculated nominal secondary current is 25 A at 12 V AC or 12.5 A at 24 V AC, subject to the manufacturer's winding ratings and connection instructions.
What does the 20 V primary adjustment tap do?
The 20 V adjustment tap forms part of the transformer's multi-voltage primary arrangement. The correct use and connections must be confirmed with ETE before installation.
What insulation class and voltage regulation does it have?
The transformer incorporates Class E insulation and has a specified 8% voltage regulation.
What are the dimensions and weight?
The transformer measures 120 × 100 × 120 mm and weighs 4.7 kg.
Which enclosures are specified for the ETE MV300P2S3?
The specified enclosure references are EPH 3 or EPN 2, providing enclosure options for suitable industrial electrical installations.
Trusted by Industrial Electrical Engineers and Panel Builders
ETE MV multi-voltage control transformers provide flexible AC voltage conversion for industrial machinery and electrical automation systems. The MV300P2S3 combines a 300 VA rating, configurable 12 V or 24 V secondary outputs, Class E insulation and 8% voltage regulation for practical industrial control power applications.
Why Choose the ETE XMS150P5S6 Class II Safety/Isolating Transformer?
The ETE XMS150P5S6 is a dependable 150 VA single-phase Class II enclosed safety/isolating transformer designed to provide a nominal 24 V AC output from a 415 V AC primary supply. Part of the ETE XMS Class II transformer series, it offers isolated low-voltage AC power for industrial control panels, electrical machinery and automation equipment.
The transformer features 0/415 V primary terminals and 0/24 V secondary terminals, providing a dedicated voltage conversion arrangement for compatible industrial electrical installations. Its Class II protective insulation provides electrical protection without reliance on a protective earth connection, while the integral moulded housing provides an enclosed transformer construction.
With a rated apparent power of 150 VA, Class F insulation and flexible DIN rail or chassis mounting, the ETE XMS150P5S6 is suitable for supplying compatible 24 V AC control relays, contactors and auxiliary electrical equipment. Its dimensions of 102 × 115.5 × 106 mm and weight of 3 kg support installation within suitably designed industrial electrical cabinets.
Key Advantages
- Reliable Class II enclosed safety/isolating transformer for industrial electrical applications.
- 150 VA rated capacity suitable for low-voltage control circuits.
- 415 V AC primary input for compatible industrial electrical supplies.
- 24 V AC secondary output for suitable control and automation equipment.
- Class II protective insulation provides electrical protection without relying on protective earthing.
- Class F insulation system supports dependable thermal performance.
- Integral moulded housing provides an enclosed transformer construction.
- DIN rail or chassis mounting offers installation flexibility.
- Separate primary and secondary windings provide galvanic isolation.
- Compact industrial design suitable for control panel installations.
Key Features
- ETE XMS Class II enclosed transformer series.
- 150 VA rated apparent power.
- Single-phase transformer construction.
- 0/415 V primary terminals.
- 415 V AC nominal primary input.
- 0/24 V secondary terminals.
- 24 V AC nominal secondary output.
- Class II safety/isolating construction.
- Class F insulation system.
- Integral moulded housing.
- DIN rail or chassis mounting.
- Calculated nominal full-load secondary current of 6.25 A.
- 102 × 115.5 × 106 mm dimensions.
- 3 kg transformer weight.
Technical Specifications
- Manufacturer: ETE
- Series: XMS Class II Enclosed Safety/Isolating Transformers
- Model: XMS150P5S6
- Product type: Enclosed safety/isolating transformer
- Number of phases: Single-phase
- Rated apparent power: 150 VA
- Primary terminals: 0/415 V
- Nominal primary voltage: 415 V AC
- Secondary terminals: 0/24 V
- Output connection: 24 V
- Nominal secondary voltage: 24 V AC
- Calculated nominal full-load secondary current: 6.25 A
- Electrical protection class: Class II
- Insulation class: Class F
- Enclosure reference: Integral moulded housing
- Mounting type: DIN rail or chassis mounting
- Length: 102 mm
- Width: 115.5 mm
- Height: 106 mm
- Dimensions (L × W × H): 102 × 115.5 × 106 mm
- Weight: 3 kg
- Product range: ETE Stock Control Transformer Range
- Reference: ETE Price List March 2026
Reliable Isolated 24 V AC Power from a 415 V Supply
The ETE XMS150P5S6 uses electromagnetic induction to convert a nominal 415 V AC primary supply into a nominal 24 V AC secondary output. Its primary and secondary windings provide galvanic isolation, supporting the supply of compatible low-voltage control circuits within industrial electrical equipment.
The transformer has a rated apparent power of 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC. This makes it suitable for appropriately rated control relays, contactor coils, signalling devices and auxiliary electrical equipment. The connected load must remain within the transformer's rated capacity.
The Class II construction uses a protective insulation arrangement that does not depend on a protective earth connection. This makes the transformer suitable for electrical installations requiring Class II equipment, subject to appropriate circuit protection and compliance with the manufacturer's installation instructions.
The Class F insulation system, integral moulded housing and flexible mounting options support practical installation within industrial electrical cabinets. Its DIN rail or chassis mounting capability provides flexibility for panel builders and machinery manufacturers.
Typical Applications
- Industrial electrical control panels requiring 24 V AC.
- Machinery control systems supplied from 415 V AC.
- 24 V AC control relays and contactor coils.
- Industrial automation and auxiliary control circuits.
- Electrical signalling and monitoring equipment.
- Manufacturing and processing machinery.
- Building services systems with compatible 24 V AC controls.
- OEM electrical panel building and machinery manufacturing.
Frequently Asked Questions
What is the ETE XMS150P5S6 used for?
The ETE XMS150P5S6 is a 150 VA Class II enclosed safety/isolating transformer designed to provide nominal 24 V AC power from a 415 V AC supply for compatible industrial control equipment.
What are the primary and secondary voltages?
The transformer has 0/415 V primary terminals and 0/24 V secondary terminals, providing a nominal 24 V AC output from a 415 V AC input.
What is the rated power and calculated secondary current?
The transformer is rated at 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC.
What does Class II construction mean?
Class II construction means the transformer incorporates a protective insulation arrangement that does not rely on a protective earth connection for protection against electric shock.
Can the ETE XMS150P5S6 be DIN rail mounted?
Yes. The transformer supports DIN rail or chassis mounting, providing flexibility for suitable industrial electrical cabinet installations.
What insulation class does the transformer use?
The ETE XMS150P5S6 uses Class F insulation, a thermal insulation classification associated with a temperature limit of 155 °C.
What are the dimensions and weight?
The transformer measures 102 × 115.5 × 106 mm and weighs 3 kg.
Does the transformer have an integral enclosure?
Yes. The ETE XMS150P5S6 features an integral moulded housing as part of its Class II enclosed safety/isolating construction.
Trusted by Industrial Electrical Engineers and Panel Builders
ETE XMS Class II enclosed safety/isolating transformers provide dependable isolated AC power for industrial control equipment. The XMS150P5S6 combines a 150 VA rating, 415 V AC primary input, 24 V AC output, Class F insulation and DIN rail or chassis mounting for reliable industrial electrical installations.
Why Choose the ETE DV750P6S4 Dual-Input-Voltage Control Transformer?
The ETE DV750P6S4 is a robust 750 VA single-phase dual-input-voltage control transformer designed to provide a nominal 110 V AC secondary supply for industrial electrical control circuits, machinery and automation systems. Part of the ETE DV dual-input-voltage transformer series, it offers flexible primary supply connections for installations operating from nominal 240 V or 415 V AC.
The transformer features 0/240/415 V primary terminals and 0/110 V secondary terminals, allowing the appropriate primary voltage connection to be selected while providing a nominal 110 V AC output. This arrangement makes the DV750P6S4 suitable for industrial machinery, switchgear and electrical control equipment requiring a dedicated transformer supply.
With a rated apparent power of 750 VA, Class E insulation and specified 4% voltage regulation, the ETE DV750P6S4 provides dependable power conversion for substantial industrial control loads. Its dimensions of 150 × 108 × 145 mm, weight of 7.6 kg and specified EPN 3 enclosure reference support installation within suitably designed industrial electrical cabinets.
Key Advantages
- Reliable 750 VA dual-input-voltage control transformer for industrial applications.
- 240 V or 415 V AC primary connections provide installation flexibility.
- 110 V AC secondary output for compatible industrial control equipment.
- Single-phase construction suitable for electrical control circuits.
- 4% voltage regulation supports stable secondary voltage performance.
- Class E insulation provides dependable thermal insulation characteristics.
- 750 VA rated capacity supports substantial industrial control circuit loads.
- Separate primary and secondary windings provide galvanic isolation.
- EPN 3 enclosure reference supports selection of a suitable protective housing.
- Robust industrial construction suitable for machinery and electrical control panels.
Key Features
- ETE DV dual-input-voltage control transformer series.
- 750 VA rated apparent power.
- Single-phase transformer construction.
- 0/240/415 V primary terminals.
- Selectable 240 V or 415 V AC primary connection.
- 0/110 V secondary terminals.
- 110 V AC nominal secondary output.
- Class E insulation system.
- 4% voltage regulation.
- Calculated nominal full-load secondary current of approximately 6.82 A.
- EPN 3 enclosure reference.
- 150 × 108 × 145 mm dimensions.
- 7.6 kg transformer weight.
- Suitable for industrial electrical control and auxiliary power applications.
Technical Specifications
- Manufacturer: ETE
- Series: DV Dual-Input-Voltage Control Transformers
- Model: DV750P6S4
- Product type: Dual-input-voltage control transformer
- Number of phases: Single-phase
- Rated apparent power: 750 VA
- Primary terminals: 0/240/415 V
- Primary voltage options: 240 V AC or 415 V AC
- Secondary terminals: 0/110 V
- Output connection: 110 V
- Nominal secondary voltage: 110 V AC
- Calculated nominal full-load secondary current: Approximately 6.82 A
- Insulation class: Class E
- Voltage regulation: 4%
- Enclosure reference: EPN 3
- Length: 150 mm
- Width: 108 mm
- Height: 145 mm
- Dimensions (L × W × H): 150 × 108 × 145 mm
- Weight: 7.6 kg
- Product range: ETE Stock Control Transformer Range
- Reference: ETE Price List March 2026
Reliable 110 V AC Power for Industrial Control Systems
The ETE DV750P6S4 dual-input-voltage transformer uses electromagnetic induction to transfer electrical energy from its primary winding to an electrically isolated secondary winding. Its 0/240/415 V primary terminals allow connection to the appropriate nominal 240 V or 415 V AC supply, while the secondary provides a nominal 110 V AC output.
The transformer's 750 VA rated apparent power corresponds to a calculated nominal full-load secondary current of approximately 6.82 A at 110 V AC. This makes it suitable for compatible control relays, contactor coils, signalling equipment and auxiliary electrical systems, provided the total connected load remains within the transformer's rated capacity.
Its specified 4% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions. This characteristic is useful for industrial control equipment where a reasonably consistent AC supply is important as the connected electrical load varies.
The Class E insulation system and robust transformer construction support integration into industrial electrical cabinets and machinery control assemblies. The specified EPN 3 enclosure reference identifies the suitable enclosure option, while the transformer's 7.6 kg weight should be considered when designing the mounting arrangement.
Typical Applications
- Industrial control panels requiring a 110 V AC supply.
- Machinery control circuits operating from 240 V or 415 V AC supplies.
- 110 V AC contactors and industrial control relays.
- Electrical switchgear and auxiliary control circuits.
- Manufacturing and production machinery.
- Industrial automation and process control equipment.
- Machine tool electrical control systems.
- OEM electrical panel building and machinery manufacturing.
- Industrial control power distribution and voltage conversion.
Frequently Asked Questions
What is the ETE DV750P6S4 used for?
The ETE DV750P6S4 is a 750 VA single-phase dual-input-voltage control transformer designed to provide nominal 110 V AC power for compatible industrial control circuits and electrical equipment.
What input voltages does the ETE DV750P6S4 support?
The transformer has 0/240/415 V primary terminals, allowing connection to the appropriate nominal 240 V or 415 V AC supply.
What is the output voltage of the ETE DV750P6S4?
The transformer features 0/110 V secondary terminals and provides a nominal 110 V AC output when correctly connected.
What is the power rating of the ETE DV750P6S4?
The transformer has a rated apparent power of 750 VA, making it suitable for substantial industrial control power applications.
What is the calculated full-load secondary current?
At the nominal 110 V AC secondary output, the 750 VA rating corresponds to a calculated full-load current of approximately 6.82 A.
What insulation class does the transformer use?
The ETE DV750P6S4 incorporates Class E insulation, a thermal insulation classification associated with a temperature limit of 120 °C.
What does 4% voltage regulation mean?
The specified 4% voltage regulation describes the change in secondary voltage between no-load and rated-load operation, helping engineers assess voltage stability under varying control circuit loads.
What are the dimensions and weight?
The transformer measures 150 × 108 × 145 mm and weighs 7.6 kg.
Which enclosure is specified for the ETE DV750P6S4?
The specified enclosure reference is EPN 3, which should be selected according to the requirements of the intended electrical installation.
Trusted by Industrial Electrical Engineers and Panel Builders
ETE DV dual-input-voltage control transformers provide dependable voltage conversion for industrial electrical systems. The DV750P6S4 combines a 750 VA rating, selectable 240 V or 415 V AC primary connections, a 110 V AC secondary output, Class E insulation and 4% voltage regulation for reliable industrial control power applications.