ETE XMS300P5S6 Class II Enclosed Safety Transformer 300VA 0/415V to 0/24V

ETE XMS300P5S6 Class II Enclosed Safety Transformer 300VA 0/415V to 0/24V

ETE XMS300P5S6 is a 300 VA single-phase Class II enclosed safety/isolating transformer with a 415 V AC primary, 24 V AC secondary, Class F insulation, integral moulded housing and chassis-only mounting.

SKU: XMS300P5S6MPN: XMS300P5S6
Price
List Price £67.80 ex VAT
Your Price (ex VAT)
£67.80
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £67.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£67.80

Why Choose the ETE XMS300P5S6 300 VA Class II Enclosed Safety/Isolating Transformer?

The ETE XMS300P5S6 is a 300 VA single-phase Class II enclosed safety/isolating transformer designed to provide a nominal 24 V AC secondary supply from a 415 V AC primary input. Part of the ETE XMS transformer series, it combines Class II electrical construction, an integral moulded housing and chassis mounting for industrial control panels, machinery and automation equipment.

Featuring 0/415 V primary terminals and 0/24 V secondary terminals, the XMS300P5S6 provides dedicated AC voltage transformation for compatible low-voltage industrial control circuits. Its Class II construction incorporates protective insulation arrangements, while its safety/isolating transformer design provides electrical separation between the primary and secondary circuits. This makes it a practical choice for installations requiring an enclosed transformer with a defined 415 V to 24 V AC voltage configuration.

The XMS300P5S6 is specified for chassis mounting only, allowing installation on a suitably supported equipment mounting surface. With Class F insulation, dimensions of 126 × 136 × 127 mm and a weight of 5 kg, it offers electrical panel builders, OEM machinery manufacturers and maintenance engineers a practical solution for supplying compatible 24 V AC control equipment.

Key Advantages

  • 300 VA rated capacity provides a dedicated low-voltage AC supply for compatible industrial control equipment.
  • 415 V AC primary input supports installations with an appropriate nominal industrial supply.
  • 24 V AC secondary output is suitable for compatible control, signalling and automation circuits.
  • Class II electrical construction incorporates protective insulation arrangements for electrical safety.
  • Safety/isolating transformer design provides electrical separation between the primary and secondary circuits.
  • Integral moulded housing provides an enclosed transformer assembly.
  • Chassis mounting allows the transformer to be secured to a suitable mounting surface within machinery or electrical equipment.
  • Class F insulation provides a defined thermal insulation classification.
  • 126 × 136 × 127 mm dimensions provide clear information for electrical panel space planning.
  • 5 kg weight enables suitable mechanical support and mounting arrangements to be specified.
  • Dedicated 415 V to 24 V AC transformation simplifies transformer selection for compatible low-voltage control applications.
  • Single-phase construction is suitable for dedicated industrial control power transformation.

Key Features

  • ETE XMS Class II enclosed safety/isolating transformer series.
  • 300 VA rated apparent power.
  • 0.3 kVA transformer capacity.
  • Single-phase transformer configuration.
  • Class II electrical construction.
  • Enclosed safety/isolating transformer design.
  • Primary terminal configuration: 0/415 V.
  • Nominal primary voltage: 415 V AC.
  • Secondary terminal configuration: 0/24 V.
  • Nominal secondary output: 24 V AC.
  • Integral moulded housing.
  • Chassis mounting only.
  • Insulation class: F.
  • Length: 126 mm.
  • Width: 136 mm.
  • Height: 127 mm.
  • Weight: 5 kg.
  • Suitable for appropriately designed industrial electrical installations requiring a nominal 24 V AC control supply from a 415 V AC source.

Reliable Class II 24 V AC Control Power for Industrial Automation

The ETE XMS300P5S6 provides a straightforward method of transforming a nominal 415 V AC primary supply into a 24 V AC secondary supply. Its 300 VA rated capacity makes it suitable for compatible industrial control equipment where the combined apparent power demand remains within the transformer's rating. Typical loads may include AC control relays, contactor coils, signalling devices and other electrical equipment designed for 24 V AC operation.

A key feature of the XMS300P5S6 is its Class II electrical construction. Class II equipment incorporates protective insulation arrangements designed to provide protection against electric shock without relying on a protective earth connection for its protective insulation system. The transformer's safety/isolating designation provides electrical separation between the primary and secondary circuits, supporting appropriately engineered low-voltage control power installations. Class II electrical construction is distinct from the transformer's Class F thermal insulation rating.

The integral moulded housing provides an enclosed transformer format, while the specified chassis-only mounting arrangement allows the unit to be installed on a suitable equipment mounting surface. Unlike smaller XMS models that may offer DIN rail installation, the XMS300P5S6 must be chassis mounted. The mounting surface and fixings should be suitable for its 5 kg weight and the conditions of the installation.

At its rated capacity, the calculated nominal secondary current is approximately 12.5 A at 24 V AC. This figure is derived from the 300 VA rating and nominal output voltage rather than a separately verified manufacturer current rating. The calculated ideal primary current is approximately 0.72 A at 415 V AC, excluding transformer losses and magnetising current. Suitable primary and secondary circuit protection, conductor sizing, ventilation and electrical clearances remain essential for dependable operation.

When selecting a transformer for control circuits containing contactors, solenoids or other inductive devices, both the continuous load and any short-duration inrush demand should be considered. The transformer's 300 VA rating alone does not establish its permissible short-duration inrush capability, so the complete load profile should be checked against the manufacturer's installation and application guidance.

Typical Applications

  • 24 V AC industrial control circuits.
  • Electrical control panels supplied from compatible 415 V AC systems.
  • Industrial machinery requiring a dedicated 24 V AC control supply.
  • Chassis-mounted machinery control equipment.
  • Industrial automation and OEM machinery.
  • Control relays and contactors with compatible 24 V AC coils.
  • Industrial signalling and indication circuits.
  • Motor control panels requiring a compatible 24 V AC supply.
  • Building control equipment designed for 24 V AC operation.
  • Machinery electrical cabinets and control enclosures.
  • Electrical equipment requiring an appropriately specified isolating transformer.
  • Electrical panel building and control system integration.
  • Replacement or upgrade projects requiring a compatible 300 VA, 415 V to 24 V AC chassis-mounted enclosed transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer ETE
Rated Power (VA) 300 VA
Primary Voltage 0/415V
Secondary Voltage 0/24V
Phase Single Phase
Series XMS Class II Enclosed Safety/Isolating Transformers
Model XMS300P5S6
Product type Enclosed safety/isolating transformer
Transformer configuration Single-phase
Electrical construction Class II
Rated apparent power 300 VA
Rated capacity 0.3 kVA
Primary terminals 0/415 V
Nominal primary voltage 415 V AC
Secondary terminals 0/24 V
Nominal secondary voltage 24 V AC
Output connection 24 V AC
Calculated nominal secondary current Approximately 12.5 A at 24 V, based on 300 VA
Calculated ideal primary current Approximately 0.72 A at 415 V, based on 300 VA and excluding transformer losses
Insulation class F
Housing Integral moulded housing
Mounting method Chassis mounting only
DIN rail mounting Not specified for this model
Length 126 mm
Width 136 mm
Height 127 mm
Dimensions (L × W × H) 126 × 136 × 127 mm
Weight 5 kg
Enclosure reference Integral moulded housing
Product range ETE Stock Control Transformers
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE XMS300P5S6 used for?

The ETE XMS300P5S6 is a 300 VA single-phase Class II enclosed safety/isolating transformer used to provide a nominal 24 V AC supply from a 415 V AC primary input for compatible industrial control circuits, electrical panels and automation equipment.

What is the power rating of the ETE XMS300P5S6?

The transformer has a rated apparent power of 300 VA (0.3 kVA). The combined apparent power demand of connected equipment should remain within the transformer's specified rating.

What primary voltage does the XMS300P5S6 require?

The transformer features 0/415 V primary terminals and is designed for a nominal 415 V AC primary supply.

What secondary voltage does the XMS300P5S6 provide?

The transformer features 0/24 V secondary terminals and provides a nominal 24 V AC output when connected to its specified primary supply.

What does Class II mean for the ETE XMS300P5S6?

Class II construction means the transformer incorporates protective insulation arrangements designed to provide protection against electric shock without relying on a protective earth connection for its protective insulation system. Correct installation and suitable circuit protection remain essential.

Is the ETE XMS300P5S6 an isolating transformer?

Yes. The XMS300P5S6 is specified as a Class II enclosed safety/isolating transformer. It provides electrical separation between the primary and secondary circuits for compatible applications, subject to correct installation and the requirements of the complete electrical system.

Can the ETE XMS300P5S6 be mounted on a DIN rail?

No. The ETE XMS300P5S6 is specified for chassis mounting only. DIN rail mounting is not a stated mounting option for this model.

How should the XMS300P5S6 be mounted?

The transformer must be chassis mounted on an appropriate equipment mounting surface. The mounting arrangement and fixings should support its 5 kg weight and meet the manufacturer's installation requirements.

What is the calculated secondary current at 24 V?

Based on its 300 VA rating and nominal 24 V AC output, the calculated secondary current is approximately 12.5 A. This is a calculated value rather than a separately verified manufacturer current rating, and actual loading must comply with the manufacturer's requirements.

What insulation class does the ETE XMS300P5S6 use?

The transformer uses Class F insulation, providing a defined thermal insulation classification. This is separate from its Class II electrical construction.

What are the dimensions and weight of the ETE XMS300P5S6?

The transformer measures 126 × 136 × 127 mm (L × W × H) and weighs 5 kg. These dimensions and its weight should be considered when planning the chassis mounting arrangement.

Does the XMS300P5S6 have an integral enclosure?

Yes. The XMS300P5S6 is supplied with an integral moulded housing. Depending on the installation environment, the overall electrical assembly may still require an additional protective cabinet or enclosure.

Can the XMS300P5S6 supply several 24 V AC control devices?

Yes, provided the connected devices are compatible with a 24 V AC supply and their combined apparent power demand is within the transformer's 300 VA rating. Any simultaneous inrush loads and other application-specific requirements should also be considered.

What should be considered when installing the ETE XMS300P5S6?

Installation should account for the specified 415 V AC primary supply, 24 V AC secondary output, 300 VA capacity, suitable circuit protection, conductor sizing, ventilation and the chassis-only mounting requirement. The mounting arrangement must support the transformer's 5 kg weight, and all connections should follow the manufacturer's instructions.

Trusted by Industrial Panel Builders and Automation Engineers

ETE XMS Class II enclosed safety/isolating transformers offer a practical solution for industrial control applications requiring enclosed AC voltage transformation and defined mounting arrangements. With a 415 V primary, 24 V secondary, 300 VA capacity, Class II construction, Class F insulation and chassis mounting, the XMS300P5S6 provides electrical panel builders, OEM machinery manufacturers and automation engineers with a versatile option for dependable low-voltage AC control power.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...