ETE XMS50P5S6 Class II Enclosed Safety Transformer 50VA 0/415V to 0/24V

ETE XMS50P5S6 Class II Enclosed Safety Transformer 50VA 0/415V to 0/24V

ETE XMS50P5S6 is a 50 VA single-phase Class II enclosed safety/isolating transformer with 0/415V primary terminals, 0/24V secondary terminals, 24 V AC output, Class F insulation, an integral moulded housing and DIN rail or chassis mounting.

SKU: XMS50P5S6MPN: XMS50P5S6
Price
List Price £32.90 ex VAT
Your Price (ex VAT)
£32.90
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £32.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£32.90

Why Choose the ETE XMS50P5S6 Class II Enclosed Safety/Isolating Transformer?

The ETE XMS50P5S6 is a compact 50 VA single-phase Class II enclosed safety/isolating transformer designed to provide a dedicated 24 V AC output from a nominal 415 V AC primary supply. Part of the ETE XMS stock control transformer range, it combines an integral moulded housing, Class II construction and flexible mounting options in a practical solution for industrial electrical control panels, machinery and auxiliary AC circuits.

Featuring primary terminals marked 0/415V and secondary terminals marked 0/24V, the XMS50P5S6 provides straightforward voltage transformation for compatible 24 V AC equipment. Its Class II construction is a defining feature of the XMS range, providing a double-insulated or reinforced-insulated protection concept rather than relying on protective earthing of accessible conductive parts. The transformer is supplied in an integral moulded housing and is suitable for DIN rail or chassis mounting, offering flexibility during electrical panel design and installation.

With a rated apparent power of 50 VA, Class F insulation and compact dimensions of 90 × 106 × 87 mm, the ETE XMS50P5S6 is well suited to applications requiring a dedicated low-voltage AC supply without the bulk of a larger control transformer. Weighing 1.3 kg, it provides a practical enclosed transformer option for panel builders, electrical contractors, OEM machinery manufacturers and industrial maintenance engineers.

Key Advantages

  • 50 VA rated apparent power for compatible 24 V AC control and auxiliary circuits.
  • Class II construction using a double-insulated or reinforced-insulated protection concept.
  • Enclosed safety/isolating transformer design for industrial electrical applications.
  • 415 V AC nominal primary input for compatible industrial electrical supplies.
  • 24 V AC secondary output for suitable low-voltage AC equipment.
  • Integral moulded housing for a self-contained enclosed transformer assembly.
  • DIN rail mounting option for integration into compatible electrical control cabinets.
  • Chassis mounting option for alternative equipment installation arrangements.
  • Class F insulation for industrial transformer applications.
  • Provides electrical isolation between the primary and secondary circuits.
  • Compact 90 × 106 × 87 mm dimensions for space-conscious electrical installations.
  • 1.3 kg weight for practical handling and installation.
  • Suitable for appropriately rated industrial control, signalling and auxiliary AC equipment.

Key Features

  • ETE XMS enclosed safety/isolating transformer series.
  • Single-phase transformer construction.
  • 50 VA total rated apparent power.
  • Class II construction.
  • Primary terminal markings: 0/415V.
  • Nominal primary voltage: 415 V AC.
  • Secondary terminal markings: 0/24V.
  • Nominal secondary output: 24 V AC.
  • Insulation class: F.
  • Enclosure: Integral moulded housing.
  • Mounting options: DIN rail or chassis.
  • Electrical isolation between primary and secondary circuits.
  • Suitable for compatible industrial 24 V AC control applications.
  • Dimensions: 90 × 106 × 87 mm.
  • Weight: 1.3 kg.
  • Included in the ETE Stock Control Transformer Range, March 2026.

Class II Enclosed 24 V AC Transformer for Industrial Control Applications

The ETE XMS50P5S6 is designed for applications requiring a 24 V AC supply derived from a nominal 415 V AC input. Its primary terminals are marked 0/415V, while the secondary terminals are marked 0/24V. This straightforward input and output arrangement makes it suitable for equipment designed to operate from a dedicated 24 V AC transformer supply, provided the electrical load remains within the specified 50 VA rating.

A key feature of the XMS50P5S6 is its Class II construction. Class II electrical equipment uses double or reinforced insulation as its protective measure, rather than depending on protective earthing of accessible conductive parts. This construction should not be confused with the transformer's separate Class F insulation specification, which describes the thermal classification of its insulation system. Both classifications are relevant to product selection, but they address different aspects of electrical design.

The transformer also features an integral moulded housing and supports DIN rail or chassis mounting. DIN rail mounting can simplify integration into suitably arranged electrical cabinets, while chassis mounting offers an alternative for machinery and equipment with dedicated mounting positions. The enclosure reference describes the supplied housing; it does not, by itself, establish an ingress protection rating or suitability for exposed outdoor environments.

Its 50 VA total rated apparent power must be considered when selecting connected equipment. At a nominal 24 V output, 50 VA corresponds to approximately 2.08 A of apparent-power-based output current under rated conditions. This calculated value is a sizing reference rather than a separately specified manufacturer current rating. Connected equipment must remain within the transformer's permitted operating limits, including any relevant starting or inrush requirements.

Installation should be undertaken by suitably qualified personnel in accordance with the manufacturer's instructions and applicable electrical requirements. Appropriate primary and secondary circuit protection, conductor selection, ventilation, clearances and mechanical support must be provided. The Class II construction should be maintained as intended, without modifications that could compromise the transformer's insulation or protective design.

Typical Applications

  • 24 V AC industrial control circuits.
  • Industrial electrical control panels and cabinets.
  • Compatible 24 V AC relay and contactor control circuits.
  • Low-voltage AC auxiliary equipment.
  • Industrial signalling and indication circuits.
  • OEM machinery and equipment assemblies.
  • DIN rail-mounted electrical control installations.
  • Chassis-mounted machinery control equipment.
  • Packaging and processing machinery.
  • Small industrial automation control circuits.
  • Electrical panel manufacturing and refurbishment.
  • Compatible transformer replacement and equipment maintenance projects.
  • Applications requiring a Class II enclosed transformer with a nominal 24 V AC output.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer ETE
Rated Power (VA) 50 VA
Primary Voltage 0/415V
Secondary Voltage 0/24V
Phase Single Phase
Product range XMS Class II Enclosed Safety/Isolating Transformers
Model / SKU XMS50P5S6
Product type Enclosed safety/isolating transformer
Protection class Class II
Phase configuration Single-phase
Rated apparent power 50 VA
Primary terminals 0/415V
Nominal primary voltage 415 V AC
Secondary terminals 0/24V
Output connection 24 V AC
Insulation class F
Mounting method DIN rail or chassis mounting
Length 90 mm
Width 106 mm
Height 87 mm
Dimensions (L × W × H) 90 × 106 × 87 mm
Weight 1.3 kg
Enclosure reference Integral moulded housing
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE XMS50P5S6 used for?

The ETE XMS50P5S6 is a 50 VA single-phase Class II enclosed safety/isolating transformer used to provide a nominal 24 V AC output from a 415 V AC primary supply for compatible industrial control and auxiliary electrical equipment.

What is the power rating of the ETE XMS50P5S6?

The transformer has a rated apparent power of 50 VA. Connected equipment must be selected so that its combined operating and starting requirements remain within the transformer's permitted ratings.

What primary input voltage does the XMS50P5S6 require?

The transformer has primary terminals marked 0/415V and is specified for a nominal 415 V AC primary input.

What secondary output voltage does the XMS50P5S6 provide?

The transformer has secondary terminals marked 0/24V and provides a nominal 24 V AC output.

What does Class II mean for the ETE XMS50P5S6?

Class II refers to an electrical protection concept based on double or reinforced insulation rather than reliance on protective earthing of accessible conductive parts. Installation must preserve the manufacturer's intended protective construction.

Is Class II the same as Class F insulation?

No. Class II describes the transformer's electrical protection construction, while Class F describes the thermal classification of its insulation system. The ETE XMS50P5S6 has both Class II construction and Class F insulation.

Can the ETE XMS50P5S6 be mounted on a DIN rail?

Yes. The authoritative product specification identifies DIN rail or chassis mounting as the available mounting arrangements. The appropriate installation method should follow ETE's mounting instructions.

Does the XMS50P5S6 have an enclosed housing?

Yes. The transformer is supplied with an integral moulded housing. This is the specified enclosure reference and should not be interpreted as a particular ingress protection rating.

What are the dimensions and weight of the ETE XMS50P5S6?

The transformer measures 90 × 106 × 87 mm (length × width × height) and weighs 1.3 kg.

What is the insulation class of the XMS50P5S6?

The ETE XMS50P5S6 has Class F insulation. This is its thermal insulation classification and is separate from its Class II electrical protection construction.

How much current can a 50 VA, 24 V transformer theoretically supply?

Dividing the 50 VA apparent power rating by the nominal 24 V secondary voltage gives approximately 2.08 A. This is a calculated sizing reference, not an independently stated manufacturer current rating. The actual connected load must comply with the manufacturer's operating limits.

A Practical Choice for Industrial Control Panel Builders and Engineers

The ETE XMS50P5S6 combines 50 VA capacity, a nominal 415 V AC primary input and a dedicated 24 V AC secondary output in a compact Class II enclosed safety/isolating transformer. With Class F insulation, an integral moulded housing and flexible DIN rail or chassis mounting, it offers a practical solution for compatible industrial control and auxiliary AC power applications.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...