2CTB802401R1500 ABB OVR PV T2 40-1500 P TS Photovoltaic Surge Protective Device

2CTB802401R1500 ABB OVR PV T2 40-1500 P TS Photovoltaic Surge Protective Device

ABB 2CTB802401R1500 OVR PV T2 40-1500 P TS is a pluggable Type 2 photovoltaic surge protective device for 1500 V DC systems with 40 kA maximum discharge current, 15 kA nominal discharge current, 5 kV voltage protection level and remote signalling.

SKU: 2CTB802401R1500MPN: 2CTB802401R1500
Price
List Price £468.98 ex VAT
Your Price (ex VAT) Save 25%
£351.74 25% OFF
You save £117.24 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £351.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£351.74

Why Choose the ABB OVR PV T2 40-1500 P TS Surge Protective Device?

The ABB OVR PV T2 40-1500 P TS 2CTB802401R1500 is a Type 2 surge protective device (SPD) specifically designed for high-voltage photovoltaic DC installations. Part of ABB's OVR PV range, it helps protect PV arrays, inverters and associated DC equipment against transient overvoltages resulting from indirect lightning events and other electrical disturbances.

Designed for photovoltaic systems with a maximum continuous operating voltage of 1500 V DC, the OVR PV T2 40-1500 P TS provides a maximum discharge current Imax of 40 kA and a nominal discharge current In of 15 kA, based on the standard 8/20 µs surge-current waveform. Its voltage protection level Up is 5 kV, with protection provided between DC+, DC− and ground.

The P configuration features replaceable pluggable cartridges, while the TS auxiliary contact provides remote status signalling through one normally open and one normally closed contact. With thermally protected varistor technology, a visual end-of-life indicator and an IP20 enclosure, the 2CTB802401R1500 provides a serviceable surge protection solution for string/combiner boxes, PV inverters and other 1500 V DC photovoltaic equipment.

Key Advantages

  • Purpose-designed Type 2 surge protection for photovoltaic DC systems.
  • Suitable for PV systems with a maximum continuous operating voltage of 1500 V DC.
  • 40 kA maximum discharge current (Imax) for robust transient surge handling.
  • 15 kA nominal discharge current (In) using an 8/20 µs waveform.
  • TS auxiliary contact enables remote monitoring of SPD status.
  • Pluggable replaceable cartridges simplify maintenance and replacement.

Key Features

  • ABB OVR PV T2 photovoltaic surge protection range.
  • Type 2 / UL Type 1 C.A. surge protective device.
  • 1500 V DC maximum continuous operating voltage Ucpv.
  • 40 kA maximum discharge current Imax.
  • 15 kA nominal discharge current In.
  • 5 kV voltage protection level Up.
  • 4 kV UL voltage protection rating (VPR).
  • Two protected lines with DC+ to DC−, DC+ to ground and DC− to ground protection modes.
  • Thermally protected varistor technology.
  • Remote signalling auxiliary contact with 1 NO + 1 NC contacts.

Dedicated Surge Protection for 1500 V DC Photovoltaic Systems

Photovoltaic arrays can be exposed to transient overvoltages caused by indirect lightning events, with long DC cable runs increasing the importance of correctly coordinated surge protection. PV-specific SPDs are designed to divert surge current while limiting the transient voltage imposed on sensitive equipment such as solar inverters and monitoring electronics.

The ABB OVR PV T2 40-1500 P TS combines a 1500 V DC Ucpv rating with 40 kA Imax, 15 kA In and a 5 kV Up protection level. Its pluggable cartridge, visual status indication and TS remote signalling contact simplify maintenance and make it particularly suitable for professional high-voltage PV installations.

Typical Applications

  • 1500 V DC photovoltaic installations.
  • Solar PV string and combiner boxes.
  • Photovoltaic inverter DC-side protection.
  • Commercial solar power installations.
  • Industrial photovoltaic systems.
  • Utility-scale solar farms and generating plants.
  • PV installations requiring remote SPD status monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

SPD Type Type 2
Product Series ABB OVR PV T2
Device Type Surge protection device
Series OVR PV T2
Order code 2CTB802401R1500
EAN 4053546050288
Product group Surge Protection Devices
Product type Photovoltaic Type 2 surge protective device
Application Photovoltaic DC systems
SPD classification Type 2 / UL Type 1 C.A.
Maximum continuous operating voltage Ucpv 1500 V DC
Intended PV system voltage 1500 V DC
Maximum discharge current Imax (8/20 µs) 40 kA
Nominal discharge current In (8/20 µs) 15 kA
Voltage protection level Up 5 kV
Voltage protection rating VPR 4 kV
Protection modes DC+ to DC− / DC+ to ground / DC− to ground
Number of protected lines 2
Short-circuit current rating Iscpv / SCCR 10 kA
Technology Thermally protected varistor
Response time <25 ns
End-of-life indicator Green = functional / Red = replace
Degree of protection IP20
Operating temperature −40 to +80 °C
Maximum altitude 2000 m
Construction Pluggable
Replacement cartridge OVR PV T2 40-1500 C, 2CTB802402R1500
Remote signalling Yes
Auxiliary contacts 1 NO + 1 NC
Dimensions (H × W × D) 99 × 54 × 73 mm
Weight 329 g
Standards IEC 61643-31, UL 1449 5th edition

Frequently Asked Questions

What is the ABB OVR PV T2 40-1500 P TS?

The ABB 2CTB802401R1500 is a Type 2 photovoltaic surge protective device designed for PV systems with a maximum continuous operating voltage of 1500 V DC, featuring pluggable cartridges and remote status signalling.

What is the maximum discharge current of the ABB OVR PV T2 40-1500 P TS?

The device has a maximum discharge current Imax of 40 kA using an 8/20 µs surge-current waveform.

What is the nominal discharge current of 2CTB802401R1500?

The ABB 2CTB802401R1500 has a nominal discharge current In of 15 kA using an 8/20 µs waveform.

Can the cartridge in the OVR PV T2 40-1500 P TS be replaced?

Yes. The device has a pluggable construction and uses the ABB OVR PV T2 40-1500 C replacement cartridge, order code 2CTB802402R1500.

Does the ABB OVR PV T2 40-1500 P TS provide remote signalling?

Yes. The TS version includes an auxiliary contact with one normally open and one normally closed contact, enabling compatible external equipment to monitor the operating status of the surge protective device.

Trusted Photovoltaic Surge Protection from ABB

ABB OVR PV surge protective devices provide solar installers, electrical engineers and system integrators with purpose-designed transient-overvoltage protection for high-voltage photovoltaic DC systems, helping safeguard inverters, combiner boxes and associated electrical equipment.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice